Related Experiment Video
Updated: Sep 27, 2025

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
Published on: November 7, 2016
Concept of Placement of Fiber-Optic Sensor in Smart Energy Transport Cable under Tensile Loading
Monssef Drissi-Habti1, Neginhal Abhijit1, Manepalli Sriharsha1
1COSYS Department, Université Gustave Eiffel, Champs/Marne, F-77447 Marne-la-Valleée, France.
Abstract:
Due to the exponential growth in offshore renewable energies and structures such as floating offshore wind turbines and wave power converters, the research and engineering in this field is experiencing exceptional development. This emergence of offshore renewable energy requires power cables which are usually made up of copper to transport this energy ashore. These power cables are critical structures that must withstand harsh environmental conditions, handling, and shipping, at high seas which can cause copper wires to deform well above the limit of proportionality and consequently break. Copper, being an excellent electric conductor, has, however, very weak mechanical properties. If plasticity propagates inside copper not only will the mechanical properties be affected, but the electrical properties are also disrupted. Constantly monitoring such large-scale structures can be carried out by providing continuous strain using fiber-optic sensors (FOSs). The embedding of optical fibers within the cables (not within the phase) is practiced. Nevertheless, these optical fibers are first introduced into a cylinder of larger diameter than the optical fiber before this same fiber is embedded within the insulator surrounding the phases. Therefore, this type of embedding can in no way give a precise idea of the true deformation of the copper wires inside the phase. In this article, a set of numerical simulations are carried-out on a single phase (we are not yet working on the whole cable) with the aim of conceptualizing the placement of FOSs that will monitor strain and temperature within the conductor. It is well known that copper wire must never exceed temperatures above 90 °C, as this will result in shutdown of the whole system and therefore result in heavy maintenance, which would be a real catastrophe, economically speaking. This research explores the option of embedding sensors in several areas of the phase and how this can enable obtaining strain values that are representative of what really is happening in the conductor. It is, therefore, the primary objective of the current preliminary model to try to prove that the principle of embedding sensors in between copper wires can be envisaged, in particular to obtain an accurate idea about strain tensor of helical ones (multi-parameter strain sensing). The challenge is to ensure that they are not plastically deformed and hence able to transport electricity without exceeding or even becoming closer to 90 °C (fear of shutdown). The research solely focuses on mechanical aspects of the sensors. There are certainly some others, pertaining to sensors physics, instrumentation, and engineering, that are of prime importance, too. The upstream strategy of this research is to come up with a general concept that can be refined later by including, step by step, all the aspects listed above.
More Related Videos
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
Related Concept Videos
Cable Subjected to a Distributed Load
Cable Subjected to Concentrated Loads
Cable Subjected to Its Own Weight
A generalized loading function is employed to analyze a cable subjected to its own weight. This function considers the force acting along the cable's arc length rather than its projected length, providing a more accurate...
Energy Stored In A Coaxial Cable
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic...
Cable: Problem Solving
Tension