A Study on Double Inputs Direct Contact and Single Output Capacitively Coupled Conductivity Detector

Shuangfei Zhang1, Hongyan Yuan1, Dan Xiao1

  • 1College of Chemical Engineering, Sichuan University, Chengdu 610017, China.

Summary

An improved conductivity detector (DISODCD) enhances sensitivity and lowers the limit of detection for analytes. This new sensor design offers improved performance and robustness against contamination, making it suitable for practical applications.

Related Concept Videos

Controlled-Current Coulometry: Overview01:27

Controlled-Current Coulometry: Overview

Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
344
Controlled-Potential Coulometry: Electrolytic Methods01:17

Controlled-Potential Coulometry: Electrolytic Methods

Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential...
309
Design Example: Capacitance Multiplier Circuit01:20

Design Example: Capacitance Multiplier Circuit

In integrated circuit technology, a capacitance multiplier is often utilized to produce a larger capacitance value when a small physical capacitance falls short. This is achieved by a circuit that multiplies capacitance values by a factor of up to 1000, such that a 10-pF capacitor can replicate the performance of a 100-nF capacitor.
The circuit illustrated in Figure 1 below incorporates two op-amps, with the first operating as a voltage follower and the second acting as an inverting amplifier.
1.0K
Equivalent Capacitance01:19

Equivalent Capacitance

Multiple capacitors can be connected in a circuit in series or parallel configuration. When the capacitor combination is connected to a battery, the potential drop across each capacitor and the magnitude of charge stored in the individual capacitor depends on the type of the connection. The capacitor combination is replaced by a single equivalent capacitor that stores the same amount of charge as the combination for a given potential difference.
The following strategies are adopted to calculate...
1.6K
Controlled-Current Coulometry: Coulometric Titration01:18

Controlled-Current Coulometry: Coulometric Titration

Coulometric titrations are a form of titrimetric analysis where the reagent is generated electrically, and its amount is evaluated based on current and generating time. The electron serves as the standard reagent. The procedure is similar to conventional titrations, such as endpoint detection.
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
256
Dielectric Polarization in a Capacitor01:31

Dielectric Polarization in a Capacitor

The presence of a dielectric medium in a capacitor not only changes the voltage and capacitance but also affects the electric field. In general, dielectrics can be of two types: polar and nonpolar. In a polar dielectric, the positive and negative charges in the molecules are separated by a distance and hence have a permanent dipole moment. In contrast, no such charge separation exists in a nonpolar dielectric, however the nonpolar molecules get polarized in the presence of an external electric...
5.1K