Pre-clinical Comparison of a High-Definition 3-Dimensional Exoscope and an Operating Microscope: A Prospective
Armando De Virgilio1,2, Andrea Costantino1,2, Bianca Maria Festa1,2
1Department of Biomedical Sciences, Humanitas University, Milan, Italy.
Objective:
The high-definition 3D operating exoscope is a new tool for surgical visualization and magnification that was designed to replace the operating microscope. However, the paucity of studies that have prospectively compared the two systems has made it difficult to draw clear recommendations. The purpose of this study was to compare the operating exoscope and the operating microscope in first-time users in a pre-clinical setting.
Methods:
Twenty-eight consecutive medical students were prospectively enrolled and randomized in a crossover design. Each student performed four exercises that required basic microsurgical skills. A tailored questionnaire (Comparison Assessment Tool) was used to subjectively compare the two systems using a 5-point Likert scale. The time needed to perform each task was recorded. A post-intervention cross-sectional survey was conducted to assess the overall quality of the trial session.
Results:
The operating exoscope was preferred over the operating microscope by most of the students in all items of the Comparison Assessment Tool, particularly with regard to "focusing" and "image quality" (n = 25, 92.6%). A significant difference between groups was found in two exercises that were easier to perform with the operating exoscope. Most of the students considered the overall quality of the evaluation experience to be "very good" (n = 25, 92.6%).
Conclusions:
The exoscope allows first-time users to better perform basic microsurgical tasks in a simulated clinical scenario compared to the operating microscope. Further prospective comparative studies will be needed to validate our preliminary findings in an actual clinical scenario.
More Related Videos
06:19Comparison of Three Clinical Stereoscopic Methods for Measuring Binocular Visual Function During Amblyopic Treatment in Unilateral Amblyopia
Published on: September 27, 2024
05:14Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
Related Concept Videos
Three-Dimensional Microscopy in Microbiology
Endoscopic Procedures III: Video Capsule Endoscopy