Tetsuma Kawaji1,2, Takanori Aizawa2, Shun Hojo1
1Department of Cardiology, Mitsubishi Kyoto Hospital, Kyoto, Japan.
Background:
ExTRa Mapping™ has developed to visualize rotational activation as atrial fibrillation (AF) drivers. The current study was sought to evaluate the instability of AF drivers by ExTRa Mapping™.
Methods:
Variation of nonpassively activated ratio (%NP) among three-time repetitive recordings before and after pulmonary vein isolation (PVI) in left atrium was assessed in 26 persistent AF patients. The recoding time was set at 5 or 8 s for the respective patients. The outcome measures included %NP at each recording, mean value of the three-time recordings, and the instability index, which was defined as maximum difference per mean %NP × 100 (%).
Results:
Total 683 sites 2049 recordings were assessed. Mean %NP was 33.3(23.3-42.7)%, and higher in sites with severe (≥50%) and patchy low voltage area than those without, but not in those with severe complex fractionated atrial electrogram area. There was significant correlation between actual and mean %NP (R = 0.86, P < .001), but maximum difference among the repetitive recordings was 16(10-24)%. The instability index of %NP was 55.9(30.9-83.6)%, and significantly lower at the recordings of 8 s compared with 5 s (50.6[28.6-78.4]% vs. 60.4[35.0-90.0]%, P = .004). Furthermore, it was higher at sites with lower reliability of the recordings. After PVI, mean %NP significantly decreased (28.7[18.3-36.7]% vs. 37.7[28.7-45.7]%, P < .001), but the instability index significantly increased compared with those before PVI (60.0[35.0-92.7]% vs. 48.9[29.1-75.0]%, P = .001).
Conclusion:
Rotational activation as AF drivers assessed by ExTRa Mapping™ is unstable, and repetitive and longer recording is required for the reliable assessment even after PVI.
More Related Videos
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Related Concept Videos
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Mechanism of Cardiac Arrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias