Effects of a Radiography Checklist on Reducing Retake Exposures
1Chair of Dental Programs, Rio Salado College, Tempe, AZ and the former Director of Faculty Development, Accreditation, and Continuing Dental Education, A.T. Still University, Arizona School of Dentistry & Oral Health, Mesa, AZ, USA. monica.nenad@riosalado.edu.
Abstract:
Purpose: Typically implemented as a safety measure, checklists can reduce risks and improve patient outcomes. Checklists have been widely used in medicine, but rarely applied to dentistry. The purpose of this replication study was to evaluate the effectiveness of a dental radiography checklist intervention for improving the diagnostic value of bitewing images and reducing retake exposures.Methods: Two cohorts of dental hygiene students from programs in the same community college district participated in the mixed methods study; one as intervention group (n=22), the other as control group (n=23). The intervention group used a checklist each time bitewing images were acquired on manikins and live patients while the control group followed the usual protocol for image acquisition. Calibrated faculty evaluated all images and recorded whether images passed, failed, or required retakes. All participants completed a demographic survey at the study conclusion while the experimental group completed two additional surveys regarding perceived value of the checklist and intention to continue its use outside the educational setting. Descriptive and inferential statistics were used to analyze the data.Results: Image failure and retake rates were significantly lower in the experimental group on both manikins and live patients (p<0.001). The control group experienced a lower failure rate on patients versus manikins; however, overall retake rates were higher than the experimental group. While the retake rate improved among both groups from manikin to human exposures, the magnitude of change across groups did not differ (p=0.992). Sensor placement was the most common cause for a failing image. Participants generally considered the checklist thorough and easy to use, however there was less agreement that it improved image quality or that they would continue its use outside the educational setting.Conclusion: A radiography checklist used in an educational setting was successful in reducing bitewing image failure and retake rates, thus benefiting patient safety with reduced radiation exposure.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
X-ray Imaging
Imaging Studies III: Computed Tomography