Related Experiment Video
Updated: Sep 26, 2025

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Prognosis of Paradoxical Low-Flow Low-Gradient Aortic Stenosis: A Severe, Non-critical Form, With Surgical Treatment
Laura Galian-Gay1, Roxana Andreina Escalona Silva1, Gisela Teixidó-Turà1
1Department of Cardiology, Hospital Universitari Vall d'Hebron, CIBER-CV, Universitat Autònoma de Barcelona, Barcelona, Spain.
Objectives:
To determine the risk of mortality and need for aortic valve replacement (AVR) in patients with low-flow low-gradient (LFLG) aortic stenosis (AS).
Methods:
A longitudinal multicentre study including consecutive patients with severe AS (aortic valve area [AVA] < 1.0 cm2) and normal left ventricular ejection fraction (LVEF). Patients were classified as: high-gradient (HG, mean gradient ≥ 40 mmHg), normal-flow low-gradient (NFLG, mean gradient < 40 mmHg, indexed systolic volume (SVi) > 35 ml/m2) and LFLG (mean gradient < 40 mmHg, SVi ≤ 35 ml/m2).
Results:
Of 1,391 patients, 147 (10.5%) had LFLG, 752 (54.1%) HG, and 492 (35.4%) NFLG. Echocardiographic parameters of the LFLG group showed similar AVA to the HG group but with less severity in the dimensionless index, calcification, and hypertrophy. The HG group required AVR earlier than NFLG (p < 0.001) and LFLG (p < 0.001), with no differences between LFLG and NFLG groups (p = 0.358). Overall mortality was 27.7% (CI 95% 25.3-30.1) with no differences among groups (p = 0.319). The impact of AVR in terms of overall mortality reduction was observed the most in patients with HG (hazard ratio [HR]: 0.17; 95% CI: 0.12-0.23; p < 0.001), followed by patients with LFLG (HR: 0.25; 95% CI: 0.13-0.49; p < 0.001), and finally patients with NFLG (HR: 0.29; 95% CI: 0.20-0.44; p < 0.001), with a risk reduction of 84, 75, and 71%, respectively.
Conclusions:
Paradoxical LFLG AS affects 10.5% of severe AS, and has a lower need for AVR than the HG group and similar to the NFLG group, with no differences in mortality. AVR had a lower impact on LFLG AS compared with HG AS. Therefore, the findings of the present study showed LFLG AS to have an intermediate clinical risk profile between the HG and NFHG groups.
Related Concept Videos
Aneurysm III: Interprofessional Care
Mitral Stenosis III: Medical Management
Aortic Regurgitation III: Medical Management
Aortic Regurgitation IV: Nursing Management
Aneurysm IV: Nursing Management
Mitral Stenosis IV: Nursing Management