Stability-indicating HPLC method development and validation for simultaneous estimation of metformin, dapagliflozin, and saxagliptin in bulk drug and pharmaceutical dosage form
Related Experiment Video
Updated: Sep 26, 2025

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Krishna Rao Vankalapati1, Pallavi Alegete1, Sathyanarayana Boodida1
1Department of Chemistry, JNTUH University College of Engineering Jagtial, Jagtial, India.
Abstract:
A simple, precise, and rapid stability-indicating reversed-phase-HPLC method was developed and validated for the estimation of metformin (MET), dapagliflozin (DAP), and saxagliptin (SAX) combination in bulk and tablet dosage forms. The proposed method uses a Kromasil C18 column (150 × 4.6 mm, 5 μm) with column oven temperature of 30°C and mobile phase containing a mixture of 60% phosphate buffer (pH = 3) and 40% acetonitrile. The flow rate was set at 1.0 mL/min, and the injection volume was 10 μL. The detection was carried out at 230 nm using a photodiode array detector, and the total run time was 4 min. The proposed method was validated according to International Council for Harmonisation (ICH) guidelines for specificity, linearity, precision, accuracy, robustness, and solution stability. The method is linear over the range of 125-750 μg/mL for MET, 1.25-7.5 μg/mL for DAP, and 0.625-3.75 μg/mL for SAX. The observed correlation coefficients (R2 ) for MET, DAP, and SAX are >0.999. The proposed method is precise, and the percentage relative standard deviation was found to be between 0.4 and 0.8. The observed percentage recoveries were between 98.51 and 100.80 for all three compounds. The product was subjected to stress conditions of acid, base, oxidative, thermal, and photolytic degradation. The product was found to degrade significantly in oxidative, acid, and base hydrolysis degradation conditions, and the degradation products were well determined from the active peaks, thus proving the stability-indicating power of the method. The developed and validated stability-indicating reversed-phase-HPLC method was appropriate for quantitative determination of these drugs in pharmaceutical preparations and also for quality control in bulk manufacturing.
More Related Videos
11:17Multiplex Therapeutic Drug Monitoring by Isotope-dilution HPLC-MS/MS of Antibiotics in Critical Illnesses
Published on: August 30, 2018
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024