Delayed Hypersensitivity Reaction to Titanium-coated Polypropylene Mesh in Breast Reconstruction
Related Experiment Video
Updated: Oct 12, 2026

Biological Compatibility Profile on Biomaterials for Bone Regeneration
Published on: November 16, 2018
Eva Jouve1, Françoise Giordano-Labadie2, Gabrielle Selmes1
1Department of Surgical Oncology, Institut Claudius Regaud, Institut Universitaire du Cancer de Toulouse-Oncopole, Toulouse, France.
Abstract:
Breast implant reconstructions increasingly incorporate meshes like the synthetic nonresorbable titanium-coated polypropylene mesh commercialized as Tiloop (Pfm medical). We report the case of a 48-year-old woman, with a medical history of nickel allergy, who presented with an extensive erythematous eruption, a periprosthetic reaction, and an axillary node reaction, 18 months after a unilateral prophylactic mastectomy. We excluded infectious, sarcoidosis and carcinomatosis. The patient's medical history, the clinical evolution, and the particularly fast and complete healing after removal of the mesh were suggestive of an unusual allergic reaction to the titanium in the titanium-coated polypropylene mesh. Titanium allergies are very rare events, predominantly described in the dental and orthopedic fields. We also discussed the hypothesis of a tardive red breast syndrome related to a synthetic mesh, also mediated by immunological response as described recently in another case report.