Related Experiment Video
Updated: Sep 26, 2025

Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
Effect of repeated millings on the surface integrity of diamond burs and roughness of different CAD/CAM materials
Gülsüm Ceylan1, Faruk Emir2, Canan Doğdu3
1Department of Prosthodontics, School of Dentistry, Istanbul Medipol University, Istanbul, Turkey. gulsumcyln@gmail.com.
Objectives:
This study evaluated the surface integrity of two types of diamond burs and their effect on the roughness of different CAD/CAM materials.
Materials And Methods:
CAD/CAM materials, Vita Mark II (VM), IPS e.max CAD (EM), Celtra Duo (CD), G-Ceram (GC), and Lava Ultimate (LU) blocks were milled with CEREC MCXL. Five pairs of pointed cylinder burs (CB) and step burs (SB) were used repeatedly. The wear rate of burs was analyzed before and after milling with a scanning electron microscope (SEM) and weighing the burs. The milling time of the blocks at different milling stages was recorded from 2 (M2) to 8 times (M8) of use. The surface roughness (Ra) of blocks was measured with a profilometer. Data from the differences in surface roughness were analyzed using univariate analyses of variance and Kruskal-Wallis tests (alpha = 0.05).
Results:
For M2, the highest roughness (2.12 ± 0.1 μm) was observed with the VM block. EM blocks presented the highest roughness values (1.82 ± 0.3 μm, 1.85 ± 0.1 μm, and 1.86 ± 0.04 μm) at M4, M6, and M8, respectively. While the highest Ra values were observed for VM (2.12 to 1.43 µm), LU provided the lowest mean Ra (1.62 to 1.33 µm) among the tested materials. After the repeated use of burs up to 8 times, the surface roughness of all the tested materials decreased. Milling of LU resulted in chip deposits on the CB surface in SEM images. The duration of cutting was higher for CD and EM materials than those of other materials, but the milling duration for VM, GC, and LU blocks was similar. SB burs exhibited more wear than CB after repeated milling.
Conclusions:
A repeated number of millings more than 4 times decreased the surface integrity of the milling burs, increased the surface roughness of CAD/CAM blocks except for LU, and increased the milling duration. Increased material hardness was more detrimental on bur surface integrity.
Clinical Relevance:
During milling CAD/CAM blocks, clinicians should note that the surface integrity of milling burs decreases after 4 times of use as a function of material hardness where step burs wear quicker than pointed cylinder burs.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
06:36Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
Published on: March 14, 2025
Related Concept Videos
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Wood Surfacing
The equipment used in the surfacing process is a plane equipped with rotating blades. This tool efficiently smoothens the wood surface and can...