A New Insight on Phased Array Ultrasound Inspection in MIG/MAG Welding
José Alonso1, Santiago Pavón2, Juan Vidal2
1Applied Physics Department, University of Cadiz, CASEM, Avda. Rep. Sah. s/n, 11510 Puerto Real, Cadiz, Spain.
Abstract:
Weldment inspection is a critical process in the metal industry. It is first conducted visually, then manually and finally using instrumental techniques such as ultrasound. We made one hundred metal inert/active gas (MIG/MAG) weldments on plates of naval steel S275JR+N with no defects, and inducing pores, slag intrusion and cracks. With the objective of the three-dimensional reconstruction of the welding defects, phased array ultrasound inspections were carried out. Error-free weldment probes were used to provide the noise level. The results can be summarized as follows. (i) The top view obtained from the phased array provided no conclusive information about the welding defects. The values of the echo amplitudes were about 70 mV for pores and cracks, and greater than 150 mV for slag intrusion, all of which showed great variability. (ii) The sectional data did not lie at the same depths and they needed to be interpolated. (iii) The interpolated sectional views, or C-scans, allowed the computation of top views at any depth, as well as the three-dimensional reconstruction of the defects. (iv) The use of the simplest tool, consisting of the frequency histogram and its statistical moments, was sufficient to classify the defects. The mean echo amplitudes were 33 mV for pores, 72.16 mV for slag intrusion and 43.19 mV for cracks, with standard deviations of 8.84 mV, 24.64 mV and 12.39 mV, respectively. These findings represent the first step in the automatic classification of welding defects.
More Related Videos
08:40Ultrasonic Welding of Thermoplastic Composite Coupons for Mechanical Characterization of Welded Joints through Single Lap Shear Testing
Published on: February 11, 2016
07:38Real-time Monitoring of High Intensity Focused Ultrasound HIFU Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound HMIFU
Published on: November 3, 2015
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):