Prostate MRI: Is Endorectal Coil Necessary?-A Review
Grace Lee1, Aytekin Oto1, Mihai Giurcanu2
1Department of Radiology, University of Chicago, 5841 South Maryland Avenue, Chicago, IL 60637, USA.
Abstract:
To assess the necessity of endorectal coil use in 3 Tesla (T) prostate magnetic resonance imaging (MRI), a literature review comparing the image quality and diagnostic performance with an endorectal coil (ERC) and a without endorectal coil (NERC), with a phased array coil or a wearable perineal coil (WPC), was performed. A PubMed search of 3T prostate MRI using an endorectal coil for studies published until 31 July 2021 was performed. A total of 14 studies comparing 3T prostate MRI with and without endorectal coil use were identified. The quality scores and diagnostic performances were recorded for each study. In total, five studies compared image quality; five studies compared quality and performance; and four studies compared performance of detection, size of detected lesions, accuracy of cancer localization, and aggressiveness/staging. The use of an endorectal coil improved image quality with a higher overall signal to noise ratio, posterior and peripheral zone signal to noise ratio, high b-value attenuation diffusion coefficient (ADC) signal to noise ratio, and contrast to noise ratio. Endorectal coil use improved subjective image quality for anatomic detail on T2 weighted images (T2WI) and diffusion weighted images (DWI). Endorectal coil use had less motion artifact on DWI than non-endorectal coil use, but produced a higher occurrence of other artifacts on DWI. Endorectal coils had higher sensitivity, specificity, and positive predictive value (PPV) in the detection of overall and index lesions, as well as smaller and less aggressive lesions, missing fewer and smaller lesions than non-endorectal coils. Endorectal coils had higher sensitivity than non-endorectal coils in localizing and staging lesions. Endorectal coils improved quantitative and qualitative image quality and diagnostic performance in the detection of smaller and less aggressive cancers in 3T prostate MRI.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI