Related Experiment Video
Updated: Sep 25, 2025

Non-equilibrium Microwave Plasma for Efficient High Temperature Chemistry
Published on: August 1, 2017
Application of high precision wavelength calibration method for plasmas rotation measurement based on Fabry-Pérot
Shengyu Fu1, Xianghui Yin1, Jia Fu2
1School of Nuclear Science and Technology, University of South China, Hengyang, Hunan 421001, China.
Abstract:
Analyzing the radiation spectra of impurity ions is a widely applied diagnostic scheme for plasma ion temperature and rotation measurements on tokamaks. High precision wavelength calibration is a prerequisite for the accurate measurement of plasma parameters, especially for plasma rotation. Furthermore, the sparseness or absence of the standard spectral lines brings calibration challenges due to the narrow wavelength range. A precise wavelength calibration method is demonstrated in which the comb-like spectra generated by the Fabry-Pérot etalon can lock a series of fixed peaks as reference points in a wide wavelength range. The equal frequency intervals of the comb-like spectra are further corrected using several characteristic neon lines of known wavelengths. The experimental results indicate that the wavelength accuracy obtained by this calibration method is less than 0.005 nm, which corresponds to a rotation speed of 2.3 km/s in the toroidal direction for the beam emission spectroscopy spectrometer installed on the experimental advanced superconducting tokamak. Taking the O V(650.024 nm, n = 4 → 3) line as an example, the maximum difference in the oxygen ion rotation velocity is 3.8 km/s for the absolute rotation of ∼25 km/s, when compared with the calibration results of a standard lamp.
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Atomic Emission Spectroscopy: Lab
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...

