Low-cost, programmable infusion pump with bolus mode for in-vivo imaging
Maciej Kujawa1, Szymon Motała1, Michał Gonet2
1Faculty of Physics, Adam Mickiewicz University, Poznan, Poland.
Abstract:
Syringe pumps are routinely used in biomedical imaging laboratories for delivering contrast agents and either infusing or injecting a precise amount of liquids. Commercial syringe pumps that are developed by specialized companies are expensive and only have standard functions, which often do not meet the requirements of individual experiments. In this paper, we demonstrate an open-source single syringe pump with the possibility of adapting to the needs of a researcher. The device that was designed, is controlled by an Arduino Leonardo, along with the stepper motor driver. For sending commands and receiving the current plunger position, a C# software was developed with serial communication via USB. Additionally, the 3D models were made in a universal way, which allows for the use of any syringe size. An example of the application of the syringe pump for biomedical applications was demonstrated using electron resonance imaging (ERI). The single syringe pump tests were demonstrated by simulating the filling of a particular volume inside the resonator. This example reflects the clearance process after an intravascular (I.V) drug administration in the murine model. The experiments were performed on an ERI TM 600 tomograph. The results confirmed that the designed syringe pump allowed for controlling the infusion speed and injected volume. Moreover, we present a user-friendly and open-source graphical interface that is a low-cost alternative for commercial devices.
More Related Videos
Related Concept Videos
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
Nonlinear Pharmacokinetics: Drug Elimination for IV Bolus Injection
Following the administration of a single intravenous (IV) bolus injection, we can determine the concentration of the drug in the plasma at any given time. This calculation is achieved using a specific equation that integrates the values of Vmax and KM.
We can also...
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...