Related Experiment Video
Updated: Jul 25, 2026

Two-way Valorization of Blast Furnace Slag: Synthesis of Precipitated Calcium Carbonate and Zeolitic Heavy Metal Adsorbent
Published on: February 21, 2017
Enhanced phosphate removal by zero valent iron activated through oxidants from water: batch and breakthrough
Weilong Zeng1, Bing Li2, Xueying Lin1
1School of Environment and Energy, South China University of Technology Guangzhou 510006 China jinhuawu@scut.edu.cn + 86 20 39380569 + 86 20 39380569.
Abstract:
In this study, oxidants including hydrogen peroxide (H2O2), hypochlorite (ClO-) and persulfate (S2O8 2-) were employed to promote zero-valent iron (ZVI) corrosion and enhance phosphate (P) removal from water through batch and breakthrough experiments. Characterization results indicated that the addition of oxidant can cause large-scale corrosion of the iron surface. This subsequently generates more iron ions and active minerals, resulting in a large number of reaction-adsorption sites for P removal. Therefore, compared with the ZVI alone system (29.4%), the removal efficiency of P by oxidant/ZVI system (H2O2 : ClO- : S2O8 2- = 33.2% : 54% : 67.1%) was improved. For the oxidant/ZVI system, H2O2 can promote the corrosion of ZVI to a certain extent. However, the solution pH could be increased during the corrosion process. This leads to inhibition of P removal performance by the H2O2/ZVI system, which only increased by 12.9% to 33.2%. The reaction between NaClO and ZVI consumes less H+, and the reaction product Cl- can pierce the passivation layer on the surface of the ZVI through the pitting effect. As such, the NaClO/ZVI system attained a 54% P removal rate. Compared with H2O2 and NaClO, a better P removal effect of about 67.1% can be achieved by using Na2S2O8, since the oxidation corrosion process of Na2S2O8 does not consume H+, and it also has the strongest oxidizing properties. Furthermore, an appropriate increase in oxidant dosing (0.1-2 mM) could improve the efficiency at which of P is removed. Five batch cycle experiments showed that the oxidant/ZVI system has a higher removal capacity and longer life-span. In the long-term column running, the P removal capacity and operation life of the NaClO/ZVI column are 9.6 times and 3.2 times higher than that of the ZVI column, respectively. This work demonstrates that an oxidant/ZVI system can be an efficient method for P removal in water, which also provides a new idea for solving the problem of ZVI corrosion passivation.
More Related Videos
06:52Experimental Column Setup for Studying Anaerobic Biogeochemical Interactions Between Iron OxyHydroxides, Trace Elements, and Bacteria
Published on: December 19, 2017
08:21Optimized Procedure for Determining the Adsorption of Phosphonates onto Granular Ferric Hydroxide using a Miniaturized Phosphorus Determination Method
Published on: May 18, 2018
Related Concept Videos
Factors Affecting Solubility
Coagulation
Microbes and Other Elemental Cycles
Microbial Bioremediation of Uranium
Microbial Leaching
Acid Mine Drainage