Related Experiment Video
Updated: Sep 24, 2025

Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
Cerebral oxygen saturation as outcome predictor after transfemoral transcatheter aortic valve implantation
Philipp C Seppelt1,2, Silvia Mas-Peiro3,4, Arnaud Van Linden4,5
1Division of Cardiology, Department of Medicine III, University Hospital Frankfurt, Goethe University, Frankfurt am Main, Germany. Philipp.Seppelt@kgu.de.
Background:
Cerebral oxygen saturation (ScO2) can be measured non-invasively by near-infrared spectroscopy (NIRS) and correlates with cerebral perfusion. We investigated cerebral saturation during transfemoral transcatheter aortic valve implantation (TAVI) and its impact on outcome.
Methods And Results:
Cerebral oxygenation was measured continuously by NIRS in 173 analgo-sedated patients during transfemoral TAVI (female 47%, mean age 81 years) with self-expanding (39%) and balloon-expanding valves (61%). We investigated the periprocedural dynamics of cerebral oxygenation. Mean ScO2 at baseline without oxygen supply was 60%. During rapid ventricular pacing, ScO2 dropped significantly (before 64% vs. after 55%, p < 0.001). ScO2 at baseline correlated positively with baseline left-ventricular ejection fraction (0.230, p < 0.006) and hemoglobin (0.327, p < 0.001), and inversely with EuroSCORE-II ( - 0.285, p < 0.001) and length of in-hospital stay ( - 0.229, p < 0.01). Patients with ScO2 < 56% despite oxygen supply at baseline had impaired 1 year survival (log-rank test p < 0.01) and prolonged in-hospital stay (p = 0.03). Furthermore, baseline ScO2 was found to be a predictor for 1 year survival independent of age and sex (multivariable adjusted Cox regression, p = 0.020, hazard ratio (HR 0.94, 95% CI 0.90-0.99) and independent of overall perioperative risk estimated by EuroSCORE-II and hemoglobin (p = 0.03, HR 0.95, 95% CI 0.91-0.99).
Conclusions:
Low baseline ScO2 not responding to oxygen supply might act as a surrogate for impaired cardiopulmonary function and is associated with worse 1 year survival and prolonged in-hospital stay after transfemoral TAVI. ScO2 monitoring is an easy to implement diagnostic tool to screen patients at risk with a potential preserved recovery and worse outcome after TAVI.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...