What is the impact of dynamic contrast-enhancement sequence in the Vesical Imaging, Reporting and Data System
Thaisa Gvozdenovic Medina Bricio1, Gabriel Lion Gouvea1, Rafael Vasconcelos Barros1
1Department of Imaging, Clinical Oncology and Hematology - Ribeirao Preto School of Medicine, University of Sao Paulo, Av Bandeirantes 3900, Campus Monte Alegre, Ribeirao Preto, São Paulo, 14049-900, Brazil.
Background:
A scoring system focusing on the risk of muscle layer invasion by Bladder cancer (BCa) has been released, Vesical Imaging - Radiological and Data System (VI-RADS), with a growing interest in evaluating its diagnostic accuracy. Our goal was to assess the accuracy and reproducibility of the VI-RADS score for assessment of the vesical muscular layer with (multiparametric-mp) and without (biparametric-bp) a dynamic-contrast enhancement (DCE) sequence.
Methods:
Retrospective study conducted from July 2018 to July 2020. All patients had suspicions of BCa and underwent Magnetic Resonance Imaging (MRI) before any intervention. MRI was interpreted by two radiologists with different levels of experience, and a VI-RADS score assigned in two different sessions (3 months apart) without and with DCE. After exclusions, 44 patients with 50 lesions were enrolled. The standard of reference was transurethral resection in 18 patients (40.9%) and cystectomy in 26 patients (59.1%).
Results:
Twenty-five lesions (50%) were muscle-invasive. There was no significant difference between the two groups for gender and presence of a stalk, but mean age of NMIBCa group was significantly higher (p = 0.01). The sizes of lesions were significantly different between groups for both readers at 2.42+/- 1.58 vs. 5.70+/- 2.67 cm for reader 1 (p < 0.0001) and 2.37+/- 1.50 vs. 5.44 +/- 2.90 cm for reader 2 (p = 0.001). The area under the curve (AUC) for muscle invasion with mpVI-RADS, considering all lesions, was 0.885 +/- 0.04 (95% CI-0.79-0.98) for reader 1 and 0.924 +/- 0.04 (0.84-0.99) for reader 2, and for bpVI-RADS was 0.879+/- 0.05 and 0.916 +/- 0.04 (0.85-0.99), respectively, both differences not statistically significant (p = 0.24 and 0.07, respectively). When considering only small lesions (< 3.0 cm), the accuracy for mpVI-RADS was 0.795 +/- 0.11 (0.57-1.0) for reader1, and 0.80 +/- 0.11(0.57-1.0) for reader 2, a non-significant difference (p = 0.56) and for bpVI-RADS was 0.747 +/- 0.12 (0.50-0.99) for reader 1 and 0.80 +/- 0.11(0.57-1.0) for reader 2, a significant difference (p = 0.04). The intraclass correlation coefficient for the final score was 0.81 (0.60-1.0) for mpVI-RADS and 0.85 (0.63-1.0) for bpVI-RADS.
Conclusion:
The VI-RADS system was accurate in demonstrating muscle-invasive BCa, for both experienced and less experienced reader, regardless of the use of a DCE sequence. However, when only small lesions were assessed the difference between the two readers was significant only for the biparametric analysis. The reproducibility was similar between multiparametric and biparametric approach.
Related Concept Videos
Imaging Studies VI: Voiding Cystourethrography and Cystography
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies III: Computed Tomography
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies


