Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Integration of a micropreconcentrator with solid-phase microextraction for analysis of trace volatile organic
Sujoy Halder1, Zhenzhen Xie1, Michael H Nantz2
1Department of Chemical Engineering.
Abstract:
The analysis of toxic volatile organic compounds (VOCs) in environmental air is important because toxic VOCs induce adverse effects on human health. Although gas chromatography- mass spectrometry (GC-MS) is the standard instrument for analysis of trace VOCs in air, this mode of analysis requires preconcentration and cryogenic processes. The preconcentration and subsequent thermal desorption of VOCs require special instruments and a long time of processing sample that significantly limit applications of GC-MS for monitoring indoor and outdoor VOC levels. Using a microfabricated preconcentrator for VOC analysis also has the challenge of a large sample volume for concentration. Using solid-phase microextraction (SPME) for VOC analysis by GC-MS often approaches the limit of detection of the GC-MS instrument for trace VOCs in air. This work reports a simple method to integrate microfabricated preconcentrators with commercial SPME fibers in a two-stage concentration processes to achieve rapid and reliable measurement of trace VOCs in air by GC-MS. We designed and fabricated a preconcentrator with micropillars in a microfluidic chamber to support sorbents and to increase the heat transfer rate to the sorbents for rapid thermal desorption. The effects of air flow rates through the preconcentrator on VOCs adsorption and thermal desorption were optimized for increasing analytical accuracy of VOCs measurements. The integration of a micropreconcentrator with SPME enabled measurements of sub-ppb levels of benzene, toluene, ethylbenzene, and xylene (BTEX), and trichloroethylene (TCE) in environmental air by GC-MS.
More Related Videos
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
09:19Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...