Simple and Sensitive RP-HPLC and UV Spectroscopic Methods for the Determination of Remogliflozin Etabonate in Pure
Nandeesha Itigimatha1, Kailash S Chadchan2, Basappa C Yallur1
1Visvesvaraya Technological University, Ramaiah Institute of Technology, Department of Chemistry, Bangalore, India
Abstract:
Simple, novel and selective reverse phase-high performance liquid chromatography (RP-HPLC) and ultraviolet (UV) spectroscopic methods have been developed and optimized for the determination of remogliflozin etabonate (RMZ) in bulk and dosage forms. In the HPLC method, the principal peak and internal standard peak were eluted separately at different retention times (RT) with the chromatographic conditions such as, mobile phase consisting of 0.02 M ammonium acetate buffer (pH was adjusted to 4.0 by 1.0 M ortho phosphoric acid), acetonitrile and tetrahydrofuran in the ratio 50:45:05, respectively (v/v) and the stationary phase used was C18, 5 μm, 4.6 mm x 250 mm kromasil column. The flow rate was 2.0 mL min-1, sample injection volume was 10 μL, and the wavelength of detection was fixed at 228 nm. In case UV spectroscopic method, the RMZ was diluted with pure ethanol. The RMZ showed a maximum absorbance at 228 nm. Hence throughout analysis 228 nm was used for the determination of RMZ. The RT of RMZ and internal standard, atorvastatin (ATST) were 6.2 min and 7.0 min, respectively. The resolution between the peaks was found to be more than 2.0. The total run time was fixed at 10 min. The linearity range for RP-HPLC method was found to be 10 μg mL-1 to 50 μg mL-1, at a fixed concentration of ATST. The linearity range for the UV spectroscopic method was found to be in the range of 100 to 250 μg mL-1. Regression coefficients (R2) were found above 0.999 for both of the techniques. The limit of detection and quantification for RMZ were found to be 1.0 μg mL-1 and 3.5 μg mL-1 respectively, in RP-HPLC method and 10.0 μg mL-1 and 40 μg mL-1, respectively, in UV spectroscopic method. The developed methods were found to be simple, accurate, reproducible, and precise. The RMZ can be analyzed in dual techniques, i.e., chromatographic and UV spectroscopic methods for its routine analysis.
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...