DeepCNAP: A Deep Learning Approach for Continuous Noninvasive Arterial Blood Pressure Monitoring Using
Abstract:
Arterial blood pressure (ABP) monitoring may permit the early diagnosis and management of cardiovascular disease (CVD); however, existing methods for measuring ABP outside the clinic use inconvenient cuff sphygmomanometry, or do not estimate continuous ABP waveforms. This study proposes a novel deep learning model DeepCNAP for estimating continuous BP waveform from a noninvasively measured photoplethysmography (PPG) signal in real-time. DeepCNAP was designed through the combination of deep convolutional networks and self-attention. The proposed method was constructed via 10-fold cross-validation based on the MIMIC database (the number of subjects = 942, recording time = 374.43 hours). The performance of DeepCNAP was evaluated from two perspectives: estimating ABP from PPG and classifying hemodynamically unstable events (i.e., hypertension, prehypertension, hypotension, and the normal state). The mean absolute errors of the BP estimates were 3.40 ± 4.36 mmHg for systolic BP, 1.75 ± 2.25 mmHg for diastolic BP, and 3.23 ± 2.21 mmHg for the BP waveform, indicating that DeepCNAP satisfies the standards of both the British Hypertension Society (BHS) and the Association for the Advancement of Medical Instrumentation (AAMI). From the estimated BP, hypertension, prehypertension, hypotension, and the normal state were classified with 99.44, 97.58, 92.23, and 94.64% accuracy, respectively. DeepCNAP enables feasible real-time estimation of invasively measured ABP from noninvasive PPG. With its noninvasive nature, high accuracy, and clinical relevance, the proposed model could be valuable in general wards at hospitals and for wearable devices in daily life.
More Related Videos
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement