Novel Plug Device for HeartMate 3 Explantation: First Multicenter Experience
Silvia Mariani1,2, Tong Li1, Anna Lassia Meyer3
1From the Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany.
Summary
A novel apical ring plug facilitated HeartMate3 left ventricular assist device (LVAD) explantation in seven patients. This safe and effective method resulted in all patients being discharged from intensive care unit.
Area of Science:
- Cardiovascular Surgery
- Mechanical Circulatory Support
- Heart Failure Management
Background:
- Explantation of left ventricular assist devices (LVADs) after myocardial recovery is uncommon but increasingly relevant due to the growing LVAD population.
- Novel strategies are needed for LVAD explantation, particularly for devices like the HeartMate3.
Purpose of the Study:
- To evaluate the safety and efficacy of a custom-made apical ring plug for HeartMate3 LVAD explantation.
- To assess perioperative outcomes, including intensive care unit discharge status, complications, and transfusion requirements.
Main Methods:
- Retrospective review of seven patients undergoing HeartMate3 explantation using a custom-made apical ring plug across four medical centers.
- Procedures were performed via conventional sternotomy or left lateral thoracotomy, with or without cardiopulmonary bypass.
- Outcomes included intensive care unit discharge, perioperative complications (bleeding, embolic, infectious), and transfusion needs.
Main Results:
- The custom-made apical ring plug was implanted without technical difficulties in all seven patients.
- No re-operations for bleeding, hemorrhagic, embolic, or plug-related infections were reported.
- All patients were discharged alive from the intensive care unit, with perioperative transfusions ranging from 0 to 3 units.
Conclusions:
- The novel apical ring plug appears to be a safe and effective device for HeartMate3 LVAD explantation in this initial patient series.
- Further larger studies are warranted to confirm long-term outcomes, as current use remains off-label.