Integrated Compensatory Responses in a Human Model of Hemorrhage
Published on: November 20, 2016
Critical Information from High Fidelity Arterial and Venous Pressure Waveforms During Anesthesia and Hemorrhage
Lauren D Crimmins-Pierce1, Gabriel P Bonvillain1, Kaylee R Henry1
1Department of Biomedical Engineering, University of Arkansas, Fayetteville, AR, USA.
Purpose:
Peripheral venous pressure (PVP) waveform analysis is a novel, minimally invasive, and inexpensive method of measuring intravascular volume changes. A porcine cohort was studied to determine how venous and arterial pressure waveforms change due to inhaled and infused anesthetics and acute hemorrhage.
Methods:
Venous and arterial pressure waveforms were continuously collected, while each pig was under general anesthesia, by inserting Millar catheters into a neighboring peripheral artery and vein. The anesthetic was varied from inhaled to infused, then the pig underwent a controlled hemorrhage. Pearson correlation coefficients between the power of the venous and arterial pressure waveforms at each pig's heart rate frequency were calculated for each variation in the anesthetic, as well as before and after hemorrhage. An analysis of variance (ANOVA) test was computed to determine the significance in changes of the venous pressure waveform means caused by each variation.
Results:
The Pearson correlation coefficients between venous and arterial waveforms decreased as anesthetic dosage increased. In an opposing fashion, the correlation coefficients increased as hemorrhage occurred.
Conclusion:
Anesthetics and hemorrhage alter venous pressure waveforms in distinctly different ways, making it critical for researchers and clinicians to consider these confounding variables when utilizing pressure waveforms. Further work needs to be done to determine how best to integrate PVP waveforms into clinical decision-making.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Pre-Procedural Guidelines for Assessing Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement