A publicly available dataset of out-of-field dose profiles of a 6 MV linear accelerator
Samuel C Peet1,2, Naasiha Cassim3, Tanya Kairn3,4,5
1Royal Brisbane and Women's Hospital, Herston, 4029, QLD, Australia. samuel.peet.physics@gmail.com.
Abstract:
An increase in radiotherapy-induced secondary malignancies has led to recent developments in analytical modelling of out-of-field dose. These models must be validated against measurements, but currently available datasets are outdated or limited in scope. This study aimed to address these shortcomings by producing a large dataset of out-of-field dose profiles measured with modern equipment. A novel method was developed with the intention of allowing physicists in all clinics to perform these measurements themselves using commonly available dosimetry equipment. A standard 3D scanning water tank was used to collect 36 extended profiles. Each profile was measured in two sections, with the inner section measured with the beam directly incident on the tank, and the outer section with the beam incident on a water-equivalent phantom abutted next to the tank. The two sections were then stitched using a novel feature-matching approach. The profiles were compared against linac commissioning data and manually inspected for discontinuities in the overlap region. The dataset is presented as a publicly accessible comma separated variable file containing off-axis ratios at a range of off-axis distances. This dataset may be applied to the development and validation of analytical models of out-of-field dose. Additionally, it may be used to inform dose estimates to radiosensitive implants and anatomy. Physicists are encouraged to perform these out-of-field measurements in their own clinics and share their results with the community.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Related Concept Videos
Radiation: Applications
The average...
Biological Effects of Radiation
Dose-Response Relationship: Overview
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Absorption of Radiation