Related Experiment Video
Updated: Sep 23, 2025

Validated LC-MS/MS Panel for Quantifying 11 Drug-Resistant TB Medications in Small Hair Samples
Published on: May 19, 2020
Measuring Tuberculosis Medication Adherence: A Comparison of Multiple Approaches in Relation to Urine Isoniazid
Ramnath Subbaraman1,2, Beena E Thomas3, J Vignesh Kumar3
1Department of Public Health and Community Medicine and Center for Global Public Health, Tufts University School of Medicine, Boston, Massachusetts, USA.
Background:
Nonadherence to tuberculosis medications is associated with poor outcomes. However, measuring adherence in practice is challenging. In this study, we evaluated the accuracy of multiple tuberculosis adherence measures.
Methods:
We enrolled adult Indians with drug-susceptible tuberculosis who were monitored using 99DOTS, a cellphone-based technology. During an unannounced home visit with each participant, we assessed adherence using a pill estimate, 4-day dose recall, a last missed dose question, and urine isoniazid metabolite testing. We estimated the area under the receiver operating characteristic curve (AUC) for each alternate measure in comparison to urine testing. 99DOTS data were analyzed using patient-reported doses alone and patient- and provider-reported doses, the latter reflecting how 99DOTS is implemented in practice. We assessed each measure's operating characteristics, with particular interest in specificity-that is, the percentage of participants detected as being nonadherent by each alternate measure, among those who were nonadherent by urine testing.
Results:
Compared with urine testing, alternate measures had the following characteristics: 99DOTS patient-reported doses alone (area under the curve [AUC], 0.65; specificity, 70%; 95% CI, 58%-81%), 99DOTS patient- and provider-reported doses (AUC, 0.61; specificity, 33%; 95% CI, 22%-45%), pill estimate (AUC, 0.55; specificity, 21%; 95% CI, 12%-32%), 4-day recall (AUC, 0.60; specificity, 23%; 95% CI, 14%-34%), and last missed dose question (AUC, 0.65; specificity, 52%; 95% CI, 40%-63%).
Conclusions:
Alternate measures missed detecting at least 30% of people who were nonadherent by urine testing. The last missed dose question performed similarly to 99DOTS using patient-reported doses alone. Tuberculosis programs should evaluate the feasibility of integrating more accurate, objective measures, such as urine testing, into routine care.
More Related Videos
12:17An In Vitro Caseum Binding Assay that Predicts Drug Penetration in Tuberculosis Lesions
Published on: May 8, 2017
09:33Visualizing Field Data Collection Procedures of Exposure and Biomarker Assessments for the Household Air Pollution Intervention Network Trial in India
Published on: December 23, 2022
Related Concept Videos
Pulmonary Tuberculosis V
Latent tuberculosis infection occurs when TB bacteria are present in a person's body, but are not causing illness or symptoms. It is not contagious, and preventive treatment is crucial to avoid the...
Pulmonary Tuberculosis IV
Several diagnostic approaches are used to detect TB. The conventional method is the Tuberculin Skin Test (TST), also known as the Mantoux test. However, this method has...
Pulmonary Tuberculosis I
Causative Organism
The primary infectious agent causing tuberculosis is Mycobacterium tuberculosis, a slow-growing, acid-fast, aerobic rod that exhibits sensitivity to heat and ultraviolet light. Instances of Mycobacterium bovis and Mycobacterium avium contributing to the development of TB infection are rare.
Mode of...
Pulmonary Tuberculosis II
Here is a detailed explanation of its pathophysiology:
Transmission: The process begins when a person inhales droplet nuclei containing M. tuberculosis. These are typically released into the air when an individual with pulmonary or...
Urine Studies II: Urine Culture and Sensitivity Test
Methods for Studying Drug Absorption: In vitro
The diffusion cell method uses a two-compartment cell, including a donor compartment with the drug solution, which simulates the environment where the drug is applied, and a receptor compartment with a buffer solution, which simulates the environment...