Modified precordial lead ECG SafOne on electrocardiography recordings
Wan Nishfa Dewi1, Safri Safri2, Iswadi Hasyim Rosma3
1Department of Medical Surgical Nursing, Faculty of Nursing, Universitas Riau, Pekanbaru-Riau, Indonesia. wan.dewi@lecturer.unri.ac.id.
Scientific Reports
|May 13, 2022
Summary
The modified precordial lead ECG SafOne shows no significant difference in electrocardiography (ECG) recording artefacts compared to standard ECG. This new lead is usable for accurate ECG recordings.
Area of Science:
- Cardiology
- Medical Devices
- Electrocardiography
Background:
- Precordial lead placement variability can cause electrocardiography (ECG) inaccuracy.
- Developing adaptable ECG tools is crucial for improving diagnostic accuracy.
Purpose of the Study:
- To evaluate the modified precordial lead ECG SafOne for ECG recordings.
- To assess ECG SafOne's impact on artefact generation compared to standard ECG.
Main Methods:
- 14 subjects underwent ECG recordings using both standard and modified ECG SafOne precordial leads.
- Artefacts in ECG recordings were measured and identified.
- A t-test was used to compare artefact data between the two methods.
Main Results:
- Artefacts in ECG SafOne recordings were minimal (1.19% in lead II, 1.79% in lead III).
- Statistical analysis revealed no significant difference in artefacts between ECG SafOne and standard ECG (p=0.096).
Conclusions:
- The modified precordial lead ECG SafOne does not significantly increase artefacts in ECG recordings.
- ECG SafOne is a viable alternative to standard precordial leads for ECG recording.
Related Concept Videos
Electrocardiogram Fundamentals
890
Introduction
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
890
Electrocardiogram
3.3K
An electrocardiogram (ECG or EKG) is a critical diagnostic tool that records the electrical signals produced by the heart during each heartbeat. This recording is achieved through electrodes placed strategically on the arms, legs, and chest. The electrocardiograph amplifies these signals and produces 12 distinct tracings, offering a comprehensive understanding of the heart's electrical activity.
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
3.3K
Electrophysiology of Normal Cardiac Rhythm
6.9K
The normal cardiac rhythm is a synchronized electrical activity that facilitates the regular and coordinated contraction of the heart muscle. This process is essential for efficient blood circulation throughout the body. The fundamental elements involved in establishing and maintaining this rhythm include the unique electrical properties of cardiac muscle cells, the sinoatrial (SA) node's pacemaker function, the specialized conducting system, and the ionic mechanisms underlying each phase...
6.9K
Correlation between ECG and Cardiac Cycle
8.6K
The electrical signals recorded on an electrocardiogram (ECG) occur before the mechanical processes of contraction and relaxation during the cardiac cycle.
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
8.6K
Cardiac Action Potential
2.9K
Cardiac action potentials are essential for proper heart function, enabling the rhythmic contractions needed for adequate blood circulation. Nodal cells and Purkinje fibers, specialized for electrical conduction, generate these action potentials.
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
2.9K
ECG Interpretation of Rhythms
4.5K
An electrocardiogram (ECG)graphically represents the heart's electrical activity on ECG paper or a monitor.
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
4.5K