Related Experiment Video
Updated: Sep 23, 2025

Cellular Lipid Extraction for Targeted Stable Isotope Dilution Liquid Chromatography-Mass Spectrometry Analysis
Published on: November 17, 2011
Stable Carbon Isotope Analysis of Hexachlorocyclohexanes by Liquid-Liquid Extraction Gas Chromatography Isotope Ratio
Cuiping Gao1, Yunlong Wang1, Yu Xia1
1Key Laboratory of Eco-Restoration of Regional Contaminated Environment, Shenyang University, Ministry of Education, Shenyang 110044, China.
Abstract:
Compound specific isotope analysis (CSIA) and enantiomer specific isotope analysis (ESIA) are powerful tools for assessing the fate of hexachlorocyclohexanes (HCHs) in the environment. However, there is no systematic study on the CSIA and ESIA analysis test methods of the carbon isotopes of HCHs in water and soil environments, in particular the isotope fractionation in the pre-concentration process. We endeavored to test the compatibility of CSIA and ESIA with the liquid-liquid extraction method of HCHs in water. The results showed that there were negligible changes in the δ13C of HCHs after extraction, indicating that liquid-liquid extraction can be used as a pre-concentration method for the determination of δ13C of HCHs in water. The optimized method was validated and then applied to differentiate three HCHs from different manufacturers, to identify in situ degradation of HCHs of groundwater from a contaminated site and to resolve the carbon isotope fractionation occurring in the α-HCH oxidation by CaO2/Fe(II) Fenton system. The results showed that the same reagents from different manufacturers have different carbon isotope compositions, and different isomers from the same manufacturer also have different isotope compositions, showing useful evidence in identifying the source of HCHs. The more enriched δ13C in the down-gradient wells indicated that HCHs have undergone biodegradation or/and chemical reactions in the groundwater system of the site. Carbon isotopic enrichment factors (εC) of -1.90 ± 0.10‱ were obtained in the oxidation process. Hence, the method validated in this study has great potential as a method for identifying the degradation of HCHs in a water environment.
More Related Videos
Related Concept Videos
Mass Spectrometry: Isotope Effect
Mass Spectrometry: Cycloalkane Fragmentation
For example, cyclohexane molecular ions have a mass-to-charge ratio (m/z) of 84, which tends to produce a stronger signal than linear alkanes like hexane. This stability comes from...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Mass Spectrometry: Long-Chain Alkane Fragmentation
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...

