Agreement in measurements of ultrasonography-derived periodontal diagnostic parameters among multiple raters: A
Jad Majzoub1, Lorenzo Tavelli2, Shayan Barootchi1
1Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, MI, USA.
Objective:
The aim of this study was to investigate the reproducibility of measurements of ultrasound-derived periodontal diagnostic parameters (PDPs) among raters.
Study Design:
Periodontists with various degrees of ultrasound experience were invited to measure 3 PDPs: soft tissue height (STH), soft tissue thickness (STT), and crestal bone thickness (CBT) on 37 human periodontal ultrasound scans acquired at the midfacial site of non-molar maxillary teeth. After an online training session and a 2-week calibration exercise, intraclass correlation coefficients (ICCs) were estimated with mixed linear regression models. The interrater mean absolute differences (MADs) were calculated among the raters and between the raters and a reference standard examiner.
Results:
Thirteen raters participated in the study. MADs among the 13 raters were 0.18 mm (STH), 0.16 mm (STT), and 0.12 mm (CBT). ICC values for STH, STT, and CBT were 0.83, 0.77, and 0.76, respectively. The MADs between the raters and the reference standard were 0.23 mm (STH), 0.19 mm (STT), and 0.14 mm (CBT). Survey results showed that ultrasound has diagnostic value and is generally easy to learn.
Conclusions:
Within the limitations of this study, good agreement was observed among ultrasound learners with various degrees of experience when measuring ultrasound-derived PDPs.