Related Experiment Video
Updated: Sep 23, 2025

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Evaluation of Shear Bond Strength of a Primer Incorporated Orthodontic Composite Resin: An In-Vitro Study
Rithika Joseph1, Nausheer Ahmed1, Abrar Younus A1
1Department of Orthodontics and Dentofacial Orthopedics, Government Dental College and Research Institute Bangalore, Bangalore, IND.
Abstract:
Introduction Newer adhesive systems are available eliminating the separate priming step during the bonding procedure thereby reducing the chances of introduction of error during bonding. The purpose of this study was to compare the shear bond strength of a primer-incorporated adhesive with that of a self-etching primer system and conventional bonding system. Materials and method Sixty-six extracted human premolars were cleaned, mounted, and randomly divided into three groups. In group A (control), 22 teeth were bonded with stainless steel orthodontic brackets using the conventional bonding system; in group B, 22 teeth were bonded using a self-etching primer system (Transbond Plus SEP, 3M Unitek, Monrovia, CA) and in group C, 22 teeth were bonded using the new primer-incorporated adhesive system (GC Ortho Connect, GC Orthodontics, Breckerfeld, Germany). After bonding, the teeth were stored in artificial saliva at 37ºC for 24 hours and debonded with a universal testing machine. The adhesive remnant index (ARI) was also evaluated. Statistical analysis was done using one-way ANOVA to compare the shear bond strength values among the three groups and Kruskal Wallis test was used for comparison of ARI scores. Results The SBS values in group A (11.60 ± 2.95 MPa), group B (9.44 ± 4.46 MPa) and group C (12.68 ± 6.25 MPa) were found to be comparable with no statistically significant difference. The ARI scores were also similar among the tested groups with the predominant site of bond failure being the bracket-adhesive interface indicating a safe bond-failure site. Conclusion GC Ortho Connect was found have clinically acceptable shear bond strength values that are comparable with that of self-etching primer and conventional bonding system. Therefore, it can be used effectively for saving the clinician's chairside time by reduction in the number of steps during bonding without compromising on the bond strength.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
05:42Detection and Removal of Tooth-Colored Composite Resin Using the Fluorescence-Aided Identification Technique
Published on: July 27, 2022