Related Experiment Video
Updated: Sep 23, 2025

Use of Capillary Aerosol Generator in Continuous Production of Controlled Aerosol for Non-Clinical Studies
Published on: April 12, 2022
Simulated and clinical aerosol spread in common periodontal aerosol-generating procedures
Anthony Puljich1, Kexin Jiao1, Ryan S B Lee1
1The University of Queensland, School of Dentistry, Brisbane, QLD, 4006, Australia.
Objectives:
This study evaluated particle spread associated with various common periodontal aerosol-generating procedures (AGPs) in simulated and clinical settings.
Materials And Methods:
A simulation study visualized the aerosols, droplets, and splatter spread with and without high-volume suction (HVS, 325 L/min) during common dental AGPs, namely ultrasonic scaling, air flow prophylaxis, and implant drilling after fluorescein dye was added to the water irrigant as a tracer. Each procedure was repeated 10 times. A complementary clinical study measured the spread of contaminated particles within the dental operatory and quantified airborne protein dispersion following 10 min of ultrasonic supragingival scaling of 19 participants during routine periodontal treatment.
Results:
The simulation study data showed that air flow produced the highest amount of splatters and the ultrasonic scaler generated the most aerosol and droplet particles at 1.2 m away from the source. The use of HVS effectively reduced 37.5-96% of splatter generation for all three dental AGPs, as well as 82-93% of aerosol and droplet particles at 1.2 m for the ultrasonic scaler and air polisher. In the clinical study, higher protein levels above background levels following ultrasonic supragingival scaling were detected in fewer than 20% of patients, indicating minimal particle spread.
Conclusions:
While three common periodontal AGPs produce aerosols and droplet particles up to at least 1.2 m from the source, the use of HVS is of significant benefit. Routine ultrasonic supragingival scaling produced few detectable traces of salivary protein at various sites throughout the 10-min dental operatory.
Clinical Relevance:
The likelihood of aerosol spread to distant sites during common periodontal AGPs is greatly reduced by high-volume suction. Clinically, limited evidence of protein contaminants was found following routine ultrasonic scaling, suggesting that the the majority of the contamination consisits of the irrigant rather than organic matter from the oral cavity.
More Related Videos
06:06Adjunctive Diode Laser Therapy and Probiotic Lactobacillus Therapy in the Treatment of Periodontitis and Peri-Implant Disease
Published on: May 9, 2022
06:14Induction of Periodontitis via a Combination of Ligature and Lipopolysaccharide Injection in a Rat Model
Published on: February 17, 2023
Related Concept Videos
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Transmission-based Precautions I: Contact, Enteric, and Droplets
Contact Precautions:
Contact precautions are the measures taken to prevent the transmission of infectious agents, especially epidemiologically important microorganisms such as MRSA or influenza, primarily transmitted through direct or indirect contact with an...