Validation of a patient safety checklist for radiological procedures in hemodynamics
Flávia Ana Pacheco1, Márcia Marques Dos Santos Felix1, Patrícia da Silva Pires2
1Universidade Federal do Triângulo Mineiro. Uberaba, Minas Gerais, Brazil.
Objectives:
to carry out cultural adaptation and validation of WHO Surgical Safety Checklist: for Radiological Interventions ONLY to Brazilian Portuguese.
Methods:
a methodological research with the following stages of the cultural adaptation process: translation of the instrument, achievement of a consensus in Portuguese, evaluation by a committee of judges, back-translation, achievement of a consensus in English, comparison with the original version, and a pre-test. The psychometric properties of the adapted version were evaluated through interobserver reliability.
Results:
the values of the kappa coefficient ranged from moderate to almost perfect in most instrument items, demonstrating that the instrument items were understandable and reliable when applied to the observed context.
Conclusions:
the cultural adaptation and validation of face and content of the instrument met the criteria of equivalence between the original and the translated instrument. The tool proved to be understandable and feasible and can be applied in invasive radiological procedures in Brazil.
More Related Videos
10:38Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
09:36Safety Precautions and Operating Procedures in an ABSL-4 Laboratory: 4. Medical Imaging Procedures
Published on: October 3, 2016
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Imaging Studies for Cardiovascular System V: CT
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: