Related Experiment Video
Updated: Sep 22, 2025

An Inertial Measurement Unit Based Method to Estimate Hip and Knee Joint Kinematics in Team Sport Athletes on the Field
Published on: May 26, 2020
Inertial Sensor-to-Segment Calibration for Accurate 3D Joint Angle Calculation for Use in OpenSim
Giacomo Di Raimondo1, Benedicte Vanwanseele1, Arthur van der Have1
1Department of Movement Sciences, Katholieke Universiteit Leuven, 3001 Leuven, Belgium.
Inertial capture (InCap) systems with musculoskeletal (MSK) models offer ecological 3D joint kinematics. A new integrated calibration method improves accuracy, making InCap a clinically viable alternative to motion capture.
Area of Science:
- Biomechanics
- Human Movement Analysis
- Wearable Technology
Background:
- Inertial capture (InCap) systems combined with musculoskeletal (MSK) models are promising for ecological 3D joint kinematics.
- Accurate sensor-to-segment calibration is a critical limitation for estimating body segment orientations.
Purpose of the Study:
- To develop and validate a novel integrated sensor-to-segment calibration method for InCap systems used with MSK models.
- To compare the accuracy of InCap-derived 3D joint kinematics using the new method against gold-standard 3D motion capture (MoCap).
Main Methods:
- Eleven healthy subjects performed walking, running, and stair ascent/descent trials wearing Xsens InCap and Vicon MoCap systems.
- A novel integrated calibration method was developed and applied to an MSK model with 3 DOF hip and knee joints.
- Root Mean Square Error (RMSE), Range of Motion (ROM), peak values, and R-squared were calculated and compared between InCap and MoCap.
Main Results:
- The integrated calibration method reduced RMSE for hip and knee joints below 5 degrees.
- No statistically significant differences were observed between InCap and MoCap kinematics across all analyzed movements.
- The developed method demonstrated improved sensor-to-segment calibration accuracy compared to MoCap.
Conclusions:
- The novel integrated calibration method enhances the accuracy of 3D joint kinematics estimation using InCap systems with MSK models.
- This approach provides a clinically applicable and easy-to-use solution for accurate human movement analysis.
- InCap systems, with this improved calibration, offer a viable alternative to MoCap in ecological settings.
More Related Videos
Related Concept Videos
Kinematic Equations - III
Using the kinematic equations,...
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
Three-Dimensional Force System
Relative Motion Analysis using Rotating Axes - Acceleration
Time differentiation is...
Kinematic Equations: Problem Solving

