Related Experiment Video
Updated: Feb 14, 2026

Clinical-oriented Three-dimensional Gait Analysis Method for Evaluating Gait Disorder
Published on: March 4, 2018
Evaluating Gait Quality in People with Hip Osteoarthritis During Habitual and Fast Walking Using a Trunk Inertial
Jiahui Wang1, Abner Sergooris2, Kristoff Corten2
1Human Movement Biomechanics Research Group, Department of Movement Sciences, KU Leuven, 3001 Leuven, Belgium.
Abstract:
Hip osteoarthritis (OA) affects the entire joint and significantly alters gait. Assessing gait through a single trunk inertial measurement unit (IMU) in clinical settings offers a more practical alternative to complex laboratory settings, allowing for the capture of natural gait movements with valuable biomechanical insights. We evaluated (1) whether gait quality differs between individuals with hip OA and healthy controls during habitual and fast walking, (2) whether gait changes from habitual to fast walking differ between groups. Forty individuals with hip OA and 40 age-matched healthy controls underwent 25-m habitual walk and 40-m fast walk. Six gait quality parameters-step symmetry, stride symmetry, stability, smoothness, regularity, and complexity-were analyzed from the IMU signals. During habitual walking, individuals with hip OA exhibited reduced symmetry and stability and several vertical impairments. During fast walking, individuals with hip OA continued to show reduced step symmetry and a more constrained gait in the mediolateral direction. Additionally, people with hip OA also showed limited adjustments when transitioning from habitual to fast walking, in contrast to the significant adjustments observed in healthy controls. These findings indicate that gait in individuals with hip OA is impaired during habitual and fast walking, with limited adaptations across the transition between the two conditions.
More Related Videos
06:52An Inertial Measurement Unit Based Method to Estimate Hip and Knee Joint Kinematics in Team Sport Athletes on the Field
Published on: May 26, 2020
05:52Lower-Limb Biomechanical Characteristics Associated with Unplanned Gait Termination Under Different Walking Speeds
Published on: August 25, 2020
Related Concept Videos
Measurement: Standard Units
Measurement: Derived Units
Units of Measurement
There are various well-known historical measurement systems, such as the Babylonian system, the Roman system, the Egyptian system, the Olympian system, the British system, and the Indus...
Units and Standards of Measurement
Measurements of physical quantities are...
Inertial Frames of Reference
Non-inertial Frames of Reference