Thermal Properties of Lightweight Steel Concrete Wall Panels under Different Humidity Conditions
Vladimir Rybakov1, Irina Ananeva2, Anatoly Seliverstov3
1Institute of Civil Engineering, Peter the Great St. Petersburg Polytechnic University, 195251 St. Petersburg, Russia.
Abstract:
The paper presents the thermal properties of lightweight steel concrete wall panels under different humidity conditions: under normal operation conditions and high moisture of the structure. The total thermal resistance (considering thermal inhomogeneity) of the enclosing lightweight steel concrete structure with a thickness of 310 mm using monolithic low-density foam concrete (density grade of D200), at an equilibrium humidity of 5% and 8%, was experimentally established. It was equal to 4.602 m2.0C/W and 4.1 m2.0C/W, respectively. In the dry state, the total thermal resistance of this structure was 5.59 m2.0 C/W, which corresponds to a thermal conductivity coefficient of 0.057 m °C/W. The influence of both horizontal and vertical joints of lightweight steel concrete wall panels and the absence of thermoprofiles on thermal properties was insignificant when using heat-insulating gaskets. The actual total thermal resistance of the structure was 2.5-2.8 times higher than that obtained by calculation under high-humidity conditions (29-32%). At the same time, the decrease in the value compared to the same value at an equilibrium humidity of 5% was only 4-6%. This indicates the good workability even of a structure with high-humidity foam concrete if the reduced total thermal resistance is complied with by the standardized one.
More Related Videos
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
10:00Experimental Protocol to Determine the Chloride Threshold Value for Corrosion in Samples Taken from Reinforced Concrete Structures
Published on: August 31, 2017
Related Concept Videos
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
Masonry in Cold and Hot Weather Conditions
Other key practices include keeping masonry units...
Masonry Cavity Walls
Maintaining a clean cavity during construction...
Composite Masonry Walls
Hot Weather Concreting
Mitigating the heat increase in concrete can be economically achieved by shading aggregate stockpiles to prevent heating from solar radiation,...
Posttensioned Masonry Walls
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...