Related Experiment Video
Updated: Sep 22, 2025

The Modified Single-working Portal Technique Using Lasso-loop Stitch with Needle for Arthroscopic Subscapularis Repair
Published on: August 8, 2025
Comparison of Fixed- and Variable-Loop Button Fixation in Arthroscopic Anterior Cruciate Ligament Reconstruction
Vijay Chandru1, Santhosh M S1, Sujana Theja J S1
1Orthopaedics and Traumatology, Jagadguru Sri Shivarathreeshwara Hospital, Jagadguru Sri Shivarathreeshwara Academy of Higher Education and Research, Mysuru, IND.
Abstract:
Introduction With the advent of fixed- and variable-loop suspensory fixation devices for arthroscopic anterior cruciate ligament (ACL) reconstruction, a maximum number of grafts can be placed within the femoral tunnel. Although several biomechanical studies have been conducted comparing these two devices, only a few comparative clinical studies are available. This study was conducted to compare the functional outcomes of arthroscopic ACL reconstruction using fixed-loop devices with those of variable-loop devices by determining their effect on graft laxity clinical assessment and patient-reported outcome scores. Methodology Out of 32 patients (27 males and five females) who underwent primary ACL reconstruction using tripled hamstring autograft, fixed- and variable-loop devices were used for 13 and 19 patients, respectively. Thirteen patients in each group were evaluated over a period of one year using the Lysholm knee score. Six patients in the variable-loop group had only six months of follow-up. Anterior drawer and Lachman tests were performed at six-month and one-year follow-ups, respectively. Results The mean ages of patients in the fixed- and variable-loop groups were 34.5[Formula: see text]11 and 34.1[Formula: see text]9.1 years, respectively. The Lysholm knee score at six weeks was fair in 7.7% of the patients in the fixed-loop group when compared to 52.6% of those in the variable-loop group (p<0.05). All the other parameters were comparable between the two groups. One patient in each group had ligament laxity at six-month and one-year follow-up, respectively. Conclusion This study showed no statistically significant difference in graft laxity or functional outcomes of arthroscopic ACL reconstruction with fixed- and variable-loop devices, except for a better patient-reported outcome score in the variable-loop group at six weeks of follow-up. Hence, there is a need for more comparative studies in this direction.
More Related Videos
08:30Surgical Retrieval, Isolation and In vitro Expansion of Human Anterior Cruciate Ligament-derived Cells for Tissue Engineering Applications
Published on: April 30, 2014
05:44Author Spotlight: Double Posteromedial Approach for Treating Posterior Cruciate Ligament Cysts
Published on: October 20, 2023