Related Experiment Video
Updated: Sep 22, 2025

Ice Generation and the Heat and Mass Transfer Phenomena of Introducing Water to a Cold Bath of Brine
Published on: March 13, 2017
Effect of dilutant concentration on the performance of environment-friendly mixed refrigerants used in domestic
Nagarjuna Kumma1, Satya Sai Harish Kruthiventi2
1Low Temperature Laboratory, Department of Mechanical Engineering, National Institute of Technology Tiruchirappalli, Trichy, 620015, India.
Abstract:
This paper presents the environment-friendly mixture compositions of hydrocarbons (HC)- and hydrofluorocarbon (HFC)-based ternary mixtures that can be better alternatives for R134a in domestic refrigeration units. Combustible refrigerant HCs (R290, R600, R600a) and HFCs (R152a and R161) are used along with the dilutants R13I1, R245fa, R134a, R227ea, and R125 and their flammability studies were carried out theoretically. Minimum inerting concentration (MIC) is used to classify the flammable and non-flammable zones of the ternary mixtures. MIC points estimated with modified thermal balance method (MTBM) are compared with 62 experimental data points available in the literature. It was calculated that MTBM predicted the MIC values with in ±9%, for most of the working fluids selected in this study. R13I1 is used along with all the refrigerant (HC and HFC) combinations (as the first dilutant) while the effect of other dilutants on the system performance is carried out theoretically. It is predicted from the flammability diagram (developed in this study) that the inert effect of R227ea is higher than of R245fa, R134a, and R125. It is also observed that the drop in coefficient of performance (COP) is significant with R290/R13I1/R245fa (with increase in R245fa) mixture when compared to other combinations. Finally, mixtures R600a/R13I1/R245fa, R600a/R13I1/R227ea, R600a/R13I1/R134a, R600a/R13I1/R125, R161/R13I1/R134a, R290/R13I1/R125, R161/R13I1/R227ea, and R161/R13I1/R125 are identified as the best environment-friendly mixture compositions as alternatives to R134a. It is also calculated that the mixture R600a/R13I1/R125 possesses COP greater than 10% to R134a at the same working conditions.
Related Concept Videos
Refrigerators and Heat Pumps
A household refrigerator removes heat from...
Solution Concentration and Dilution
Turbulent Flow: Problem Solving
Temperature is a key factor in CO2 solubility. In this case, the CO2 gas and the liquid are cooled to 20°C. Lower temperatures...
Comparing Intermolecular Forces: Melting Point, Boiling Point, and Miscibility
Temporary attractive forces like dispersion are present in all molecules, whether they are polar or nonpolar. They...
Mixtures of Acids
A Mixture of a Strong Acid and a Weak Acid
In a mixture of a strong acid and a weak acid, the strong acid dissociates completely and becomes a source of almost all the hydronium ions...
Noble Gases
The elements in group 18 are noble gases (helium, neon, argon, krypton, xenon, and radon). They earned the name “noble” because they were assumed to be nonreactive since they have filled valence shells. In 1962, Dr. Neil Bartlett at the University of British Columbia proved this assumption to be false.