Related Experiment Video
Updated: Sep 22, 2025

Design of a Biocompatible Drug-Eluting Tracheal Stent in Mice with Laryngotracheal Stenosis
Published on: January 21, 2020
Comparison of Inhaled Drug Delivery in Patients With One- and Two-level Laryngotracheal Stenosis
Raluca E Gosman1,2, Ryan M Sicard2, Seth M Cohen2
1Duke University School of Medicine, Duke University Medical Center, Durham, North Carolina, U.S.A.
Objectives/Hypothesis:
Laryngotracheal stenosis (LTS) is a functionally devastating condition with high respiratory morbidity and mortality. This preliminary study investigates airflow dynamics and stenotic drug delivery in patients with one- and two-level LTS.
Study Design:
A Computational Modeling Restropective Cohort Study.
Methods:
Computed tomography scans from seven LTS patients, five with one-level (three subglottic, two tracheal), and two with two-level (glottis + trachea, glottis + subglottis) were used to reconstruct patient-specific three-dimensional upper airway models. Airflow and orally inhaled drug particle transport were simulated using computational fluid dynamics modeling. Drug particle transport was simulated for 1-20 μm particles released into the mouth at velocities of 0 m/s, 1 m/s, 3 m/s, and 10 m/s for metered dose inhaler (MDI) and 0 m/s for dry powder inhaler (DPI) simulations. Airflow resistance and stenotic drug deposition in the patients' airway models were compared.
Results:
Overall, there was increased airflow resistance at stenotic sites in subjects with two-level versus one-level stenosis (0.136 Pa s/ml vs. 0.069 Pa s/ml averages). Subjects with two-level stenosis had greater particle deposition at sites of stenosis compared to subjects with one-level stenosis (average deposition 2.31% vs. 0.96%). One-level stenosis subjects, as well as one two-level stenosis subject, had the greatest deposition using MDI with a spacer (0 m/s): 2.59% and 4.34%, respectively. The second two-level stenosis subject had the greatest deposition using DPI (3.45%). Maximum deposition across all stenotic subtypes except one-level tracheal stenosis was achieved with particle sizes of 6-10 μm.
Conclusions:
Our results suggest that patients with two-level LTS may experience a more constricted laryngotracheal airflow profile compared to patients with one-level LTS, which may enhance overall stenotic drug deposition.
Level Of Evidence:
NA Laryngoscope, 133:366-374, 2023.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Tracheostomy Suctioning II: Procedure
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques