Robotic retromuscular abdominal wall repair using an inverted TEP (iTEP) approach: surgical technique and short-term
Frederick Olivier1, Mohamed Abasbassi2, Joachim Geers2
1Department of General and Abdominal Surgery, AZ Damiaan, Gouwelozestraat 100, 8400, Ostend, Belgium. folivier@azdamiaan.be.
Purpose:
Robotic retromuscular abdominal wall repair (RAWR) for ventral hernias can be performed transabdominal or extraperitoneal by using an enhanced view totally extraperitoneal repair (eTEP). For defects in the meso- or epigastric region, an inverted approach can be used, starting the development of the totally extraperitoneal plane in the suprapubic region and progressing in a caudal-to-cranial direction (inverted TEP, iTEP). The aim of the study is to present the surgical technique and to report the short-term outcomes.
Methods:
A retrospective analysis of a prospectively maintained database was performed, including patients who underwent a robotic RAWR using the iTEP approach between December 2019 and January 2022. The surgical technique was described, and patients' characteristics and intra- and postoperative parameters were studied and compared to the TARUP technique (robotic transabdominal retromuscular umbilical prosthetic hernia repair).
Results:
Thirty-four patients were treated with an iTEP approach, and 14 patients underwent a TARUP procedure. The median length of stay was 1 day (range 1-3), and there were no intraoperative complications in both groups. One patient (3%) required reoperation after an iTEP approach for a small bowel internal herniation due to a rupture of the posterior rectus sheath. There were no recurrences or mortality with a median follow-up of 15 months (range 3-29) in the iTEP group, compared to 35 months (range 29-37) in the TARUP group.
Conclusion:
For defects in the upper abdominal region, a robotic RAWR with an iTEP approach appears to be safe and feasible. Long-term follow-up is needed to evaluate the late recurrence rate.