Related Experiment Video
Updated: Sep 21, 2025

Sandy Soil Improvement through Microbially Induced Calcite Precipitation MICP by Immersion
Published on: September 12, 2019
Evaluation of Compressive Strength and Thermal Conductivity of Sand Stabilized with Epoxy Emulsion and Polymer
Sung-Sik Park1, Jun-Woo Park2, Keun-Byoung Yoon3
1Department of Civil Engineering, Kyungpook National University, 80 Daehakro, Bukgu, Daegu 41566, Korea.
Abstract:
This paper presents findings obtained by evaluating the compressive strength, thermal conductivity, and durability of sand cylinder specimens stabilized with either epoxy emulsion (EM), acrylic polymer aqueous solution (APAS), EM-APAS mixture, or EM-APAS-lime mixture. Given the data obtained from the laboratory test, simulation analysis that uses a heat transfer fluid model of a ground-coupled heat pump (GCHP) system confirms the EM-APAS-lime binder performs best in the compressive strength and thermal conductivity; EM-APAS mixture performs best in the durability. However, the slake durability index of specimens containing EM-APAS-lime is equal to or greater than 80%. In addition, the compressive strength of sand stabilized with the EM-APAS-lime mixture is more than three times that of sand stabilized with cement. The thermal conductivity of sand stabilized with cement and that of sand treated with EM-APAS-lime mixture are 0.1 W/m·K and 0.9-1 W/m·K, respectively. It is confirmed that the heat collection of sand stabilized with EM-APAS-lime outperforms five times over that of sand stabilized with cement. These findings provide admissible evidence that the EM-APAS-lime mixture, which outperforms cement in compressive strength and thermal conductivity, is most suitable for ground improvement binder for GCHP systems.
More Related Videos
05:38Production and Analysis of Sporosarcina pasteurii Biocement Bricks Using Custom 3D-Printed Molds for Unconfined Compression Tests
Published on: March 7, 2025
09:46Protocol for Measuring the Thermal Properties of a Supercooled Synthetic Sand-water-gas-methane Hydrate Sample
Published on: March 21, 2016
Related Concept Videos
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Design Example: Managing Concrete Workability
Soundness of Cement
Effect of Sea Water on Concrete
Concrete in areas between tide marks,...
Mortar Properties