Related Experiment Video
Updated: Sep 21, 2025

Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Capnography and Pulse Oximetry Improve Fast Track Extubation in Patients Undergoing Coronary Artery Bypass Graft
Seyed Tayeb Moradian1, Fatemah Beitollahi1, Mohammad Saeid Ghiasi2
1Atherosclerosis Research Center, Nursing Faculty, Baqiyatallah university of Medical Sciences, Tehran, Iran.
Background:
Use of capnography as a non-invasive method during the weaning process for fast track extubation (FTE) is controversial. We conducted the present study to determine whether pulse oximetry and capnography could be utilized as alternatives to arterial blood gas (ABG) measurements in patients under mechanical ventilation (MV) following coronary artery bypass graft (CABG) surgery.
Methods:
In this randomized clinical trial, 70 patients, who were candidates for CABG surgery, were randomly assigned into two equal groups (n = 35), intervention and control group. In the intervention group, the ventilator management and weaning from MV was done using Etco2 from capnography and SpO2 from pulse oximetry. Meanwhile, in the control group, weaning was done based on ABG analysis. The length of intensive care unit (ICU) stay, time to extubation, number of manual ventilators setting changes, and alarms were compared between the groups.
Results:
The end-tidal carbon dioxide (ETCO2) levels in the intervention group were completely similar to the partial pressure of carbon dioxide (PaCo2) in the control group (39.5 ± 3.1 vs. 39.4 ± 4.32, p > 0.05). The mean extubation times were significantly shorter in the intervention group compared to those in the control patients (212.2 ± 80.6 vs. 342.7 ± 110.7, p < 0.001). Moreover, the number of changes in the manual ventilator setting and the number of alarms were significantly lower in the intervention group. However, the differences in the length of stay in ICU between the two groups were not significant (p = 0.219).
Conclusion:
Our results suggests that capnography can be used as an alternative to ABG. Furthermore, it is a safe and valuable monitor that could be a good alternative for ABG in this population. Further studies with larger sample sizes and on different disease states and populations are required to assess the accuracy of our findings.
Clinical Trial Registration:
Current Controlled Trials, IRCT, IRCT201701016778N6, Registered 3 March 2017, https://www.irct.ir/trial/7192.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques