Specific electrolyte effects on hemoglobin in denaturing medium investigated through electro spray ionization mass
Tiziana Pivetta1, Gloria Lusci1, Cristina Carucci2
1Dept. Chemical and Geological Sciences, University of Cagliari, Cittadella Universitaria, S.S. 554 bivio Sestu, 09042 Monserrato, Cagliari, Italy.
Abstract:
We examine Hofmeister specific ion effects of electrolytes added to protein solution under conditions minimizing electrostatic attraction between cations and positively charged protein. Hemoglobin (Hb) in aqueous solution at the denaturing pH = 2.7 is investigated in the presence of several metal chlorides, along with sodium and potassium bromides, iodides and thiocyanates, using electrospray ionization mass spectrometry (ESI-MS). Salt concentration was varied to maximize peak intensity and bell-shaped profile in the ESI-MS spectrum. The α-chain of myoglobin is identified as the main pattern of the ESI-MS spectra in all Hb-salt systems. Both peak intensity and quality of the bell-shaped profile of the protein spectrum decrease in the cation order: K+ > > Mg2+ > Li+ > > Na+ > Ca2+ ≈ Cs+ > Rb+ for Hb-Metal Chloride systems, and decrease in the anion order: Cl- > Br- > I- > SCN- for systems of both Hb-NaX and Hb-KX salts. To quantify salt addition effects two Hofmeister specific electrolyte parameters HS, and PS are proposed. HS is the mean (Hb-salt)/Hb peak intensity ratio, measured for the nine peaks used for ESI-MS spectra deconvolution, taken at the same m/z values of the Hb profile. PS is the ratio between HS standard deviation and HS, and provides a specific perturbation parameter measuring the loss of protein structure. These two Hofmeister parameters give clear evidence of the effects induced either by KCl, MgCl2 and LiCl that enhance protein peak intensity, or by NaBr, NaI, NaSCN and KSCN that induce the protein fragmentation, due to electrolyte-mediated dissociation.
More Related Videos
09:18Time-resolved ElectroSpray Ionization Hydrogen-deuterium Exchange Mass Spectrometry for Studying Protein Structure and Dynamics
Published on: April 17, 2017
08:40Millisecond Hydrogen/Deuterium-Exchange Mass Spectrometry for the Study of Alpha-Synuclein Structural Dynamics Under Physiological Conditions
Published on: June 23, 2022
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Mass Spectrometry: Overview
Mass Spectrometry: Isotope Effect
Chemical Ionization (CI) Mass Spectrometry