Simultaneous Laryngopharyngeal and Conventional Esophageal pH Monitoring
Published on: December 14, 2020
Normative values of intra-bolus pressure and esophageal compliance based on 4D high-resolution impedance manometry
Wenjun Kou1, Dustin A Carlson1, Peter J Kahrilas1
1Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.
Background:
This study aimed to quantify normative values of phase-specific intra-bolus pressure (IBP) and esophageal distensibility using 4D analysis of high-resolution-impedance manometry (HRIM).
Methods:
HRIM studies of supine swallows from 34 normal controls were analyzed with respect to the four phases of bolus transit: (1) accommodation, (2) compartmentalization, (3) peristalsis/esophageal emptying, and (4) ampullary emptying. Phase-specific IBP, bolus volume, and distensibility index (DI) in the esophageal body and esophagogastric junction (EGJ) during phases 1-3 were extracted.
Results:
The median (5-95th/IQR) IBP values were as follows: phase 1: 4.0 (-2.0-10.4/1.9-5.8) mmHg, phase 2: 5.7 (0.2-14.1/3.6-8.9) mmHg, and phase 3: 11.2 (2.9-19.4/7.7-15.1) mmHg. The median bolus volume calculated by integrating impedance planimetry cross-sectional areas was 4.1 ml during the compartmentalization phase. The EGJ-DI at max EGJ diameter during phase 2 and 3 was 2.8 (1.1-9.5/1.8-3.7) mm2 /mmHg and 6.0 (3.2-20.3/5.1-7.8) mm2 /mmHg, respectively. The phase 3 EGJ-DI values (6.0 (3.2-20.3/5.1-7.8) mm2 /mmHg) were similar to those calculated using functional lumen imaging probe (FLIP) at the 60 ml volume on the same subjects (5.8 [3.5-7.2/5.0-6.4] mm2 /mmHg).
Conclusions And Inferences:
4D-HRIM provides a standardized methodology to track the nadir impedance and provide measurements of IBP during maximal distention across phases 1-3 of bolus transit. Median IBP and delta IBP were different across the phases, supporting the need to define IBP by phase. Additionally, the EGJ-DI calculated during phase 3 was similar to the 60-ml EGJ-DI from FLIP in the same subjects suggesting that 4D-HRIM can quantify EGJ opening during primary peristalsis.
Related Concept Videos
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...