Related Experiment Video
Updated: Sep 20, 2025

Artificial Thermal Ageing of Polyester Reinforced and Polyvinyl Chloride Coated Technical Fabric
Published on: January 29, 2020
Space Charge Behavior of Thermally Aged Polyethylene Insulation of Track Cables
Zhichao Qiao1, Wangsong Wu2, Zhaowei Wang3
1CRSC Research and Design Institute Group Co., Ltd., Beijing 100070, China.
Abstract:
The interface of multi-layer insulation is a relatively weak point in the cable system during the long-term high-temperature service. Space charge is prone to continuously accumulate in the interface area, leading to the deterioration of electrical properties and even insulation failure in advance. The knowledge about thermal oxidation of polyethylene (PE) materials at the molecular level is still urgent to explore. Herein, single-layer and double-layer PE insulation, representing the typical insulation structure of frequency-shift pulse voltage track cables, were prepared and thermally aged in the oven for up to 360 h. Thermal, mechanical, electrical, and space charge characterizations were systematically carried out. Thermogravimetric analyzer and oxidation induced temperature (OIT) measurements confirmed that LDPE's thermal-oxidative aging temperature range was the lowest among the three PE groups in the O2 atmosphere. After 360 h thermal aging, the tensile property of HDPE material kept relatively stable, while the elongation at break of the other two groups was lower than 50%. Unaged HDPE exhibits apparent charge injection and migration, leading to the severe electric field distortion of 20%. Noticeable charge accumulation can be observed at the unaged double-layer sample interface due to the mismatching of DC conductivity, which play a significant role in the aged double-layer samples. This work utilizes precise thermal analysis to provide new information about the resistance ability of thermal oxidation of LDPE, FPE, and HDPE, and its influence on space charge behaviors, which is helpful for the insulation design and evaluation in cable applications.
More Related Videos
Related Concept Videos
Energy Stored In A Coaxial Cable
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic...
Cable Subjected to Its Own Weight
A generalized loading function is employed to analyze a cable subjected to its own weight. This function considers the force acting along the cable's arc length rather than its projected length, providing a more accurate...
Insulation Coordination
Cable Subjected to Concentrated Loads
Cable Subjected to a Distributed Load
Charge on a Conductor