The potential of thermal desorption-GC/MS-based analytical methods for the unambiguous identification and
Håkan Wingfors1, Lina Mörén1, Daniel Wiktelius1
1Swedish Defence Research Agency, FOI CBRN Defence and Security, Umeå, Sweden.
Abstract:
The reactive gases perfluoroisobutene and carbonyl fluoride are highly toxic and difficult to analyze in air. For this paper, the available sampling and analysis methods involving gas chromatography/mass spectrometry were investigated for their potential to give unambiguous identification and quantification of perfluoroisobutene and carbonyl fluoride, for which no such methods exist. Although high concentrations of perfluoroisobutene could be analyzed directly by manual split injection, sorbent sampling followed by thermal desorption GC/MS allowed lower concentrations to be analyzed. However, a significant degradation of perfluoroisobutene observed after thermal desorption analysis inspired the use of derivatization of perfluoroisobutene with 3,4-dimercaptotoluene. The use of Tenax TA sorbent tubes spiked with 3,4-dimercaptotoluene and trimethylamine in a molar ratio of 1:8 proved successful for the quantification of a unique perfluoroisobutene derivative, and the method was validated for atmospheres in the range of 0.13-152 ppb with a relative standard deviation of less than 20% and an accuracy of 90%. Although carbonyl fluoride was less stable than perfluoroisobutene, direct analysis was possible at high concentrations but the response was not linear. The 3,4-dimercaptotoluene derivatization method developed was also applicable for quantification of carbonyl fluoride atmospheres.
More Related Videos
07:06Investigating Long-Distance Transport of Perfluoroalkyl Acids in Wheat via a Split-Root Exposure Technique
Published on: September 28, 2022
05:22Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Atomic Absorption Spectroscopy: Atomization Methods