Related Experiment Video
Updated: Sep 8, 2025

Systematic Hearing Performance Evaluation Process for Adolescents with Cochlear Implantation at Early Ages
Published on: March 24, 2023
The Acoustic Change Complex Compared to Hearing Performance in Unilaterally and Bilaterally Deaf Cochlear Implant
Jan A A van Heteren1,2, Bernard M D Vonck1,2, Robert J Stokroos1,2
1Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, the Netherlands.
Objectives:
Clinical measures evaluating hearing performance in cochlear implant (CI) users depend on attention and linguistic skills, which limits the evaluation of auditory perception in some patients. The acoustic change complex (ACC), a cortical auditory evoked potential to a sound change, might yield useful objective measures to assess hearing performance and could provide insight in cortical auditory processing. The aim of this study is to examine the ACC in response to frequency changes as an objective measure for hearing performance in CI users.
Design:
Thirteen bilaterally deaf and six single-sided deaf subjects were included, all having used a unilateral CI for at least 1 year. Speech perception was tested with a consonant-vowel-consonant test (+10 dB signal-to-noise ratio) and a digits-in-noise test. Frequency discrimination thresholds were measured at two reference frequencies, using a 3-interval, 2-alternative forced-choice, adaptive staircase procedure. The two reference frequencies were selected using each participant's frequency allocation table and were centered in the frequency band of an electrode that included 500 or 2000 Hz, corresponding to the apical electrode or the middle electrode, respectively. The ACC was evoked with pure tones of the same two reference frequencies with varying frequency increases: within the frequency band of the middle or the apical electrode (+0.25 electrode step), and steps to the center frequency of the first (+1), second (+2), and third (+3) adjacent electrodes.
Results:
Reproducible ACCs were recorded in 17 out of 19 subjects. Most successful recordings were obtained with the largest frequency change (+3 electrode step). Larger frequency changes resulted in shorter N1 latencies and larger N1-P2 amplitudes. In both unilaterally and bilaterally deaf subjects, the N1 latency and N1-P2 amplitude of the CI ears correlated to speech perception as well as frequency discrimination, that is, short latencies and large amplitudes were indicative of better speech perception and better frequency discrimination. No significant differences in ACC latencies or amplitudes were found between the CI ears of the unilaterally and bilaterally deaf subjects, but the CI ears of the unilaterally deaf subjects showed substantially longer latencies and smaller amplitudes than their contralateral normal-hearing ears.
Conclusions:
The ACC latency and amplitude evoked by tone frequency changes correlate well to frequency discrimination and speech perception capabilities of CI users. For patients unable to reliably perform behavioral tasks, the ACC could be of added value in assessing hearing performance.
More Related Videos
09:06Cochlear Implant Surgery and Electrically-evoked Auditory Brainstem Response Recordings in C57BL/6 Mice
Published on: January 9, 2019
07:00Electrically Evoked Stapedius Reflex Measurements in Cochlear Implantation and Its Application in the Postoperative Fitting Process
Published on: June 21, 2024
Related Concept Videos
The Cochlea
Hearing
Auditory Pathway
When viewed cross-sectionally, the cochlea reveals the scala vestibuli and scala tympani flanking...
Hair Cells