Comprehensive detection of 120 additives in food using nontargeted MS data acquisition
Che-Lun Hsu1,2, Mingchih Fang1, Hui-Chun Tseng2
1Department of Food Science, National Taiwan Ocean University, 2 Beining Road, Keelung City 20224, Taiwan.
Abstract:
The compliance assessment on the labeling of food additives is a hard job, because there are nearly thousand legal food additives can be used in food, and countless illegal additives must also deal with. This study developed a non-targeted data acquisition screening method based on liquid chromatography high resolution mass spectrometry (HRMS) in which a precursor ion and two product ions of each analyte are able to be recorded. The high throughput screening method worked as foodomics that characterized and identified every food components as long as they were ionized in terms of theory. The data acquisition method called data independent acquisition (DIA) was achieved by a full scan form m/z 70-1050, and then followed wide window fragmentations of product ions recording. A full scan and the followed fragmentations generated 21 spectra in 2.6 s contributed about 6 data points for a typical 0.2-0.3 min width peak in HPLC. A detection database list of 120 additives included 79 colorants, 13 sweeteners, 12 preservatives and 7 antioxidants was established. Thirty-three commercial samples including beverages, candies, and sauces were surveyed for testing additives. Sweeteners (rebaudioside A) and flavoring agents (malic acid and fumaric acid) were found the most under declared additives. HPLC column often do not provide adequate retention for highly polar compounds such as organic acids (flavoring agents). In this study they were coeluted, but were able to be separated and determined by HRMS worked as the secondary separation tool. The surveillance results showed there is still room for food manufacturers to improve the connection between their product information and consumers.
More Related Videos
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
07:34Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Spectrometry: Overview
High-Performance Liquid Chromatography: Types of Detectors