Related Experiment Video
Updated: Sep 8, 2025

Studying Large Amplitude Oscillatory Shear Response of Soft Materials
Published on: April 25, 2019
An experimental study of tuned liquid column damper controlled multi-degree of freedom structure subject to harmonic
Mati Ullah Shah1, Muhammad Usman1
1School of Civil and Environmental Engineering (SCEE), National University of Sciences and Technology (NUST), Islamabad, Pakistan.
Abstract:
A tuned liquid column damper (TLCD) is a passive vibration control device that not only mitigates unwanted structural vibrations but also acts as a water storage facility in a building. These aspects of TLCD make its application specifically suited for building structures. Previously, many experimental works on TLCDs have been conducted considering a single degree of freedom (SDOF) structure. However, the performance of TLCDs to control the response of multi-degree of freedom (MDOF) structure has rarely been studied experimentally. Therefore, this study has investigated the performance of a tuned liquid column damper (TLCD) on a multi-degree of freedom (MDOF) structure using shake table testing. A four-storey steel frame structure equipped with TLCD at the top of the fourth storey has been studied. Experimental normalized frequency response curves for MDOF structure equipped with TLCD have been determined. For this purpose, a series of harmonic loadings including frequencies 0.65 Hz, 1.17 Hz, 1.30 Hz, 1.43 Hz and 1.95 Hz have been applied in addition to historic earthquake loading. Peak and root-mean-square (RMS) accelerations have been discussed in detail for all the applied loadings at each storey level of the structure. For comparison purposes, the percentage reductions in peak and RMS accelerations have been calculated and compared. Also, RMS displacements and inter-storey drifts have been presented for resonant and seismic excitations. Both in time and frequency domains, responses of controlled MDOF structure have been analyzed and compared with uncontrolled structure. Results confirmed that TLCD has improved the MDOF structure responses at harmonic loadings frequencies near resonance and historic earthquake excitations. Furthermore, the improvement in the responses of MDOF structure with TLCD is more prominent at harmonic loadings compared to historic earthquake loading.
More Related Videos
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
10:52Simulation of Human-induced Vibrations Based on the Characterized In-field Pedestrian Behavior
Published on: April 13, 2016
Related Concept Videos
One-Degree-of-Freedom System
A one-degree-of-freedom system is defined by an independent variable that determines its state and behavior. One example of a one-degree-of-freedom system is a simple harmonic oscillator, such as a...
Types of Damping
Stability of structures
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Damped Oscillations
Although friction and other non-conservative...
Indeterminate Structure