Related Experiment Video
Updated: Sep 8, 2025

Muscle Imbalances: Testing and Training Functional Eccentric Hamstring Strength in Athletic Populations
Published on: May 1, 2018
A New Portable Device to Reliably Measure Maximal Strength and Rate of Force Development of Hip Adduction and
Basílio A M Gonçalves1, Ricardo N O Mesquita2, Francisco Tavares3
1School of Allied Health Sciences, Griffith University, Gold Coast, Queensland, Australia.
Abstract:
Gonçalves, BM, Mesquita, RNO, Tavares, F, Brito, J, Correia, P, Santos, P, and Mil-Homens, P. A new portable device to reliably measure maximal strength and rate of force development of hip adduction and abduction. J Strength Cond Res 36(9): 2465-2471, 2022-Groin injuries are a major issue in sports involving kicking or quick changes of direction. Decreased hip adduction and abduction strength have been indicated as one of the main risk factors for groin injury. The methods currently available to measure hip adduction and abduction strength are reliable but highly dependent on the evaluator skills. Furthermore, several studies have reported the reliability of maximal strength (MVIC), but very few studies investigated the reliability of explosive strength (RFD), a parameter that has been previously shown to have a higher functional value. The aim of the current investigation was to assess the reliability of a user-independent portable dynamometer that concurrently measures MVIC and RFD. Twenty-five healthy young subjects performed maximal isometric hip adduction and abduction in both sitting and supine positions. Measurements occurred in 2 different days separated by 48-72 hours. Test-retest reliability was calculated for both MVIC and RFD. Both MVIC and RFD showed good relative reliability (intraclass correlation coefficient = 0.77-0.98) with no differences between positions or muscle actions. Measurement error was similar between positions for MVIC in both hip adduction and abduction. Measurements of RFD showed higher reliability using a time window of at least 0-100 milliseconds, and lower measurement error was observed in sitting for adduction and in supine for abduction. This study shows that portable dynamometry can be used to concurrently measure hip adduction and abduction maximal and explosive strength, with levels of reliability that are similar to previously described methods.
More Related Videos
12:59Improving Strength, Power, Muscle Aerobic Capacity, and Glucose Tolerance through Short-term Progressive Strength Training Among Elderly People
Published on: July 5, 2017
08:48Adapted Resistance Training Improves Strength in Eight Weeks in Individuals with Multiple Sclerosis
Published on: January 29, 2016