KD-Informer: A Cuff-Less Continuous Blood Pressure Waveform Estimation Approach Based on Single Photoplethysmography
Abstract:
Ambulatory blood pressure (BP) monitoring plays a critical role in the early prevention and diagnosis of cardiovascular diseases. However, cuff-based inflatable devices cannot be used for continuous BP monitoring, while pulse transit time or multi-parameter-based methods require more bioelectrodes to acquire electrocardiogram signals. Thus, estimating the BP waveforms only based on photoplethysmography (PPG) signals for continuous BP monitoring has essential clinical values. Nevertheless, extracting useful features from raw PPG signals for fine-grained BP waveform estimation is challenging due to the physiological variation and noise interference. For single PPG analysis utilizing deep learning methods, the previous works depend mainly on stacked convolution operation, which ignores the underlying complementary time-dependent information. Thus, this work presents a novel Transformer-based method with knowledge distillation (KD-Informer) for BP waveform estimation. Meanwhile, we integrate the prior information of PPG patterns, selected by a novel backward elimination algorithm, into the knowledge transfer branch of the KD-Informer. With these strategies, the model can effectively capture the discriminative features through a lightweight architecture during the learning process. Then, we further adopt an effective transfer learning technique to demonstrate the excellent generalization capability of the proposed model using two independent multicenter datasets. Specifically, we first fine-tuned the KD-Informer with a large and high-quality dataset (Mindray dataset) and then transferred the pre-trained model to the target domain (MIMIC dataset). The experimental test results on the MIMIC dataset showed that the KD-Informer exhibited an estimation error of 0.02 ± 5.93 mmHg for systolic BP (SBP) and 0.01 ± 3.87 mmHg for diastolic BP (DBP), which complied with the association for the advancement of medical instrumentation (AAMI) standard. These results demonstrate that the KD-Informer has high reliability and elegant robustness to measure continuous BP waveforms.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: