Related Experiment Video
Updated: Aug 1, 2026

A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
Extended Computed Tomography Scale Images Provide a Detailed Assessment of Metal Screws and Are Superior to Standard
Jose Labrador1, Ines Carrera2, Andy Holdsworth1
1Diagnostic Imaging Department, Davies Veterinary Specialists, Hitchin, United Kingdom.
Objectives:
(1) To compare the ability of standard computed tomography (CT) scale (SCTS) and extended CT scale (ECTS) images, produced using conventional CT technology, to provide detailed assessment of metal screws in vitro. (2) To assess how screw size, type, and orientation relative to the Z-axis of the gantry affect implant assessment. (3) To test the ability of SCTS, ECTS, and radiography to diagnose screw failure when there is negligible screw fragment displacement.
Study Design:
Part 1: 12 screws of different size, type, and composition were scanned in three orientations (parallel or 0°; oblique or 45°; and perpendicular or 90°) relative to the Z-axis of the gantry. SCTS and ECTS reconstructions were made for each screw, in each plane, to assess implant shape, structure, and diameter. Part 2: fatigue-failure was induced in four screws commonly used to stabilize canine humeral intracondylar fissures. Screws were then reassembled achieving grossly perfect apposition and alignment of the fragments. Ability to detect implant failure was tested using SCTS, ECTS, and radiography.
Results:
ECTS provided better screw assessment compared with SCTS resulting in clear visualization of the structure in 8/12 versus 0/12 screws and shape in 12/12 versus 11/12 screws; however, results were affected by screw size, type, and orientation. ECTS identified all in vitro screw fractures with negligible screw fragment displacement; however, success was affected by screw orientation: 4/4 fractures identified with a 90° angle, 1/4 for 45°, and 0/4 for 0°. SCTS and radiography did not identify any of them.
Conclusion:
The results indicate that ECTS reconstructions are useful for assessment of metal screws and for detection of nondisplaced screw fractures.
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies III: Computed Tomography

