Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

UV–Vis Spectrometers01:14

UV–Vis Spectrometers

1.5K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
1.5K
IR Spectrometers01:25

IR Spectrometers

1.4K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
1.4K
Atomic Absorption Spectroscopy: Instrumentation01:22

Atomic Absorption Spectroscopy: Instrumentation

925
An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
925
UV–Vis Spectroscopy: Molecular Electronic Transitions01:16

UV–Vis Spectroscopy: Molecular Electronic Transitions

1.8K
In Ultraviolet–Visible (UV–Vis) spectroscopy, the absorption of electromagnetic radiation is used to probe the electronic structure of molecules. This technique provides insights into molecular electronic transitions, particularly the movement of electrons between different molecular orbitals. Radiation is absorbed if the energy of the electromagnetic radiation passing through the molecule is precisely equal to the energy difference between the excited and ground states. During this...
1.8K
Raman Spectroscopy Instrumentation: Overview01:26

Raman Spectroscopy Instrumentation: Overview

529
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
529
UV–Vis Spectroscopy of Conjugated Systems01:32

UV–Vis Spectroscopy of Conjugated Systems

7.3K
Organic compounds with conjugated double bonds show strong absorption features in the UV–visible region of the electromagnetic spectrum attributed to π → π* electronic excitations. Generally, a UV–vis absorption spectrum is recorded as a plot of absorbance vs wavelength. The wavelength of maximum absorbance, which manifests as a peak in the absorption spectrum, is denoted as λmax.
One of the factors influencing λmax is the extent...
7.3K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Controlling Energy Distribution in Multilayer Nanostructures for Bioimaging and Photoelectric Conversion.

Inorganic chemistry·2026
Same author

An Absorption-Transport Reconfigurable 2D/3D/2D Architecture Enables Multispectral-Adaptive Bifacial Perovskite Photovoltaics.

Advanced materials (Deerfield Beach, Fla.)·2026
Same author

Room-temperature-prepared perovskite/Si photodetector with controllable spectral modulation and encrypted optical communication.

Optics letters·2026
Same author

DNA Aptamer-Functionalized Fluorescent Silica Nanoparticles: A Robust Strategy for Specific Detection and Bioimaging of HER2-Overexpressing Breast Cancer.

International journal of nanomedicine·2026
Same author

High-Precision In-Sensor Computing Reaching Up to 10 Bits.

Advanced materials (Deerfield Beach, Fla.)·2026
Same author

Cost-Optimized Perovskite Solar Cells Enabled by Molecularly Engineered Hole Transport.

ACS applied materials & interfaces·2026
Same journal

Generating Unconventional Spin-Orbit Torques With Patterned Phase Gradients in Tungsten Thin Films.

Advanced materials (Deerfield Beach, Fla.)·2026
Same journal

An In Situ H<sub>2</sub>S-Activated Plasmonic Nanozyme for Near-Infrared II Photo-Thermoelectric Catalytic Therapy.

Advanced materials (Deerfield Beach, Fla.)·2026
Same journal

A Recyclable and Sustainable Hydroxypropyl Methylcellulose Electrolyte for Electrochromic Devices.

Advanced materials (Deerfield Beach, Fla.)·2026
Same journal

Perovskite Heterostructures for Optoelectronic Applications.

Advanced materials (Deerfield Beach, Fla.)·2026
Same journal

Light-Written Nonvolatile Polarization via Defect-Engineered Charge Trapping.

Advanced materials (Deerfield Beach, Fla.)·2026
Same journal

Nucleation-Controlled Synthesis and a Unified Descriptor for Rational Interlayer Design of Vanadium-Oxide Cathodes toward High-Performance Zinc-Ion Batteries.

Advanced materials (Deerfield Beach, Fla.)·2026
See all related articles

Related Experiment Video

Updated: Sep 8, 2025

Influence of Hybrid Perovskite Fabrication Methods on Film Formation, Electronic Structure, and Solar Cell Performance
11:38

Influence of Hybrid Perovskite Fabrication Methods on Film Formation, Electronic Structure, and Solar Cell Performance

Published on: February 27, 2017

18.6K

A Single-Dot Perovskite Spectrometer.

Linqi Guo1, Haoxuan Sun1, Min Wang1

  • 1School of Physical Science and Technology, Jiangsu Key Laboratory of Thin Films, Center for Energy Conversion Materials and Physics (CECMP), Soochow University, Suzhou, 215006, P. R. China.

Advanced Materials (Deerfield Beach, Fla.)
|June 16, 2022
PubMed
Summary
This summary is machine-generated.

This study introduces a novel single-dot spectrometer using in situ perovskite modulation for spectral analysis. This miniaturized device achieves high resolution and fast response times, overcoming current design limitations.

Keywords:
hyper-spectrumion migrationperovskitesspectrometers

More Related Videos

High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis
13:31

High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis

Published on: December 22, 2015

15.2K
Spectral and Angle-Resolved Magneto-Optical Characterization of Photonic Nanostructures
08:01

Spectral and Angle-Resolved Magneto-Optical Characterization of Photonic Nanostructures

Published on: November 21, 2019

7.2K

Related Experiment Videos

Last Updated: Sep 8, 2025

Influence of Hybrid Perovskite Fabrication Methods on Film Formation, Electronic Structure, and Solar Cell Performance
11:38

Influence of Hybrid Perovskite Fabrication Methods on Film Formation, Electronic Structure, and Solar Cell Performance

Published on: February 27, 2017

18.6K
High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis
13:31

High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis

Published on: December 22, 2015

15.2K
Spectral and Angle-Resolved Magneto-Optical Characterization of Photonic Nanostructures
08:01

Spectral and Angle-Resolved Magneto-Optical Characterization of Photonic Nanostructures

Published on: November 21, 2019

7.2K

Area of Science:

  • Photonics and Spectrometry
  • Materials Science
  • Nanotechnology

Background:

  • Current on-chip spectrometers require integrated strategies, leading to wasted photosensitive area and hindering miniaturization.
  • Existing designs face limitations in balancing footprint size with spectral resolution.

Purpose of the Study:

  • To demonstrate a unique single-dot spectrometer design utilizing in situ modulation.
  • To overcome the footprint-resolution restriction in spectral analysis.
  • To present a new design paradigm for functional perovskite devices.

Main Methods:

  • Development of a spectrometer with a single detection point.
  • Implementation of in situ modulation through photogain control at varying bias voltages.
  • Utilizing perovskite materials for modulation.

Main Results:

  • Achieved micrometer-level footprints for the spectrometer.
  • Demonstrated a spectral resolution of approximately 5 nm.
  • Obtained a rapid response time down to 197 µs.

Conclusions:

  • The novel in situ perovskite modulation strategy breaks the traditional footprint-resolution trade-off.
  • This single-dot spectrometer design offers significant advancements in miniaturization and performance.
  • Presents a promising new direction for the development of functional perovskite devices.