Application of measurement error models to correct for systematic differences among readers and vendors in
Aisha Betoko1, Chike Nwabuo2, Bharath Ambale Venkatesh2
1Department of Epidemiology, Johns Hopkins University, Baltimore, MD, USA.
Abstract:
We illustrate the application of linear measurement error models to calibrate echocardiography measurements acquired 20 years apart in the CARDIA study. Of 4242 echocardiograms acquired at Year-5 (1990-1991), 36% were reread 20 years later. Left ventricular (LV) mass and 8 other measurements were assessed. A machine reproducibility study including 96 additional patients also compared Year-5 and Year-25 equipment. A linear measurement error model was developed to calibrate the original Year-5 measurements, incorporating the additional Year-5 reread and machine reproducibility study data, and adjusting for differences among readers and machines. Median (quartiles) of original Year-5 LV mass was 144.4 (117.6, 174.2) g before and 129.9 (103.8, 158.6) g, after calibration. The correlation between original and calibrated LV mass was 0.989 (95% confidence interval: 0.988, 0.990). The original and calibrated measurements had similar distributions. Additional comparisons of original and calibrated data supported the use of the model. We conclude that systematic differences among readers and machines have been accounted for, and that the calibrated Year-5 measurements can be used in future longitudinal comparisons. It is hoped that this paper will encourage the wider application of measurement error models.
Related Concept Videos
Uncertainty in Measurement: Accuracy and Precision
Random and Systematic Errors
Errors occurring during blood pressure monitoring
Several factors...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...